文献速递青光眼白内障与屈光手术

植入式遥测传感器揭示眼压的周内与季节变化

Weekly and seasonal changes of intraocular pressure measured with an implanted intraocular telemetry sensor.
PubMed 文献 · Br J Ophthalmol · 2020-06-04

该前瞻性多中心观察研究纳入22例原发性开角型青光眼患者(平均67.8±6.8岁,女性36.4%),在白内障手术时植入眼压遥测传感器并长期自我测量眼压。结果显示眼压周三最高、周五最低(p=0.002),冬季眼压显著高于夏季,仲冬至仲夏平均眼压降低8.1%(-1.55 mm Hg,p<0.05)。

要点

  • 眼压存在周内波动:周三平均最高,周五平均最低(p=0.002)。
  • 眼压呈季节模式:冬季显著高于夏季。
  • 仲冬至仲夏平均眼压降低8.1%(-1.55 mm Hg,p<0.05)。

核心结论

  • 研究证实眼压存在先前观察到的季节性变化,冬季眼压显著高于夏季。
  • 眼压在周五低于其他工作日。
  • 上述结果的原因尚不明确。

研究设计与样本

  • 前瞻性、开放标签、多中心观察性研究。
  • 纳入22例原发性开角型青光眼患者的22只眼,平均年龄67.8±6.8岁,女性占36.4%。
  • 患者在白内障手术时植入眼压遥测传感器,并自我测量眼压,每天至少4次。
  • 采用方差分析和Tukey多重比较校正评估各工作日和各月份间平均及峰值眼压变化的统计学显著性。

主要发现

  • 每例入组患者平均每日记录眼压测量持续721天。
  • 平均眼压周三最高、周五最低(p=0.002)。
  • 眼压全年存在显著变化,呈现季节模式。

临床怎么用

  • 临床解读眼压时应考虑周内和季节波动,冬季及周中眼压可能偏高。
  • 长期居家遥测眼压可为青光眼患者提供传统诊室测量之外的波动信息。

局限性

  • 样本量较小,仅22例患者的22只眼。
  • 患者均为原发性开角型青光眼且在白内障手术时植入传感器,结果外推需谨慎。
  • 原文未报告周内和季节变化的具体机制。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND/AIMS: To better understand seasonal and weekday intraocular pressure (IOP) variations, long-term daily IOP measurements were assessed in patients with glaucoma using an intraocular telemetric sensor. METHODS: This prospective, open-label, multicentre observational study analysed the IOP variation patterns in 22 eyes of 22 patients with primary open-angle glaucoma (67.8±6.8 years, 36.4% female) who had undergone placement of an intraocular telemetric sensor at the time of cataract surgery. The telemetric system combines an implantable IOP sensor with a hand-held reading device. Patients were instructed to self-measure their IOP as often as desired, but at least four times daily. Analysis of variance and Tukey multiple-comparison correction were used to assess the statistical significance of average and peak IOP variations between individual weekdays and months. RESULTS: Each enrolled patient recorded daily IOP measurements for an average duration of 721 days. On average, IOPs were highest on Wednesdays and lowest on Fridays (p=0.002). There were significant variations of IOP throughout the year, and IOP showed a seasonal pattern. Between mid-winter (December-January) and mid-summer months, there was a reduction in mean IOP of 8.1% (-1.55 mm Hg, p<0.05). CONCLUSION: This study confirms previously observed seasonal variations of IOP. IOP was significantly higher in winter compared with summer months. Moreover, IOP was lower on Friday than on other days. The explanation for these results is not known.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Mansouri K, Gillmann K, Rao HL, et al. Weekly and seasonal changes of intraocular pressure measured with an implanted intraocular telemetry sensor. Br J Ophthalmol. 2020. PMID: 32499329. doi:10.1136/bjophthalmol-2020-315970

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。