文献速递小儿眼科与斜弱视

刺激方向对屈光性弱视儿童视觉功能的影响

Effect of Stimulus Orientation on Visual Function in Children with Refractive Amblyopia.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2020-01-01

本研究利用图形起始-终止视觉诱发电位(POVEP)和心理物理光栅视敏度(GA)评估新诊断屈光性弱视儿童的经向各向异性模式。弱视组GA和C3振幅均差于对照组。

要点

  • 新诊断屈光性弱视儿童在研究的刺激参数下未显示显著经向各向异性。
  • 高散光(≥3.00 D)者C3振幅显著低于低(≤1.50 D)和中(1.75-2.75 D)散光者。
  • 屈光性弱视组GA较对照差约两行logMAR,C3振幅低约6 µV。

核心结论

  • 高散光对新诊断屈光性弱视儿童有不良影响,但在所研究的刺激参数下神经缺陷似乎不具有方向特异性。

研究设计与样本

  • 单眼记录沿个体主散光子午线(近似水平和垂直)的正弦波4 cpd光栅POVEP,双眼记录45°、90°、135°、180°方向刺激的POVEP。
  • 使用二项非强制选择技术评估相同子午线上的心理物理GA。

主要发现

  • 屈光性弱视组在所有结局指标上均无显著经向各向异性。
  • 事后分析显示低散光(P=0.02)和中散光(P=0.004)者C3振幅显著高于高散光者。
  • 弱视组GA较对照差约两行logMAR(单眼P=0.013;双眼P=0.014)。
  • 弱视组C3振幅较对照低约6 µV(单眼P=0.009;双眼P=0.027)。

关键数值与推荐

  • 散光分组:低≤1.50 D,中1.75-2.75 D,高≥3.00 D。
  • POVEP刺激为4 cycles per degree正弦波光栅。
  • GA差异约两行logMAR,C3振幅差异约6 µV。

临床怎么用

  • 对屈光性弱视儿童应关注高散光(≥3.00 D)对视觉皮层反应的不良影响。
  • POVEP和GA可用于评估屈光性弱视儿童的视觉功能损害程度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: We investigated and characterized the patterns of meridional anisotropies in newly diagnosed refractive amblyopes using pattern onset-offset visual evoked potentials (POVEPs) and psychophysical grating acuity (GA). METHODS: Twenty-five refractive amblyopes were recruited and compared with non-amblyopic controls from our previous study. Monocular POVEPs were recorded in response to sinewave 4 cycles per degree (cpd) grating stimuli oriented along each individual participants' principal astigmatic meridians, which were approximately horizontal (meridian 1) and vertical (meridian 2). Binocular POVEPs in response to the same stimuli, but oriented at 45°, 90°, 135°, and 180°, were recorded. Psychophysical GAs were assessed along the same meridians using a two-alternative non-forced-choice technique. The C3 amplitudes and peak latencies of the POVEPs and GAs were compared across meridians for both groups (refractive amblyopes and controls) using linear mixed models (monocular) and ANOVA (binocular), and post hoc analysis was conducted to determine if meridional anisotropies in this cohort of amblyopes were related to low (≤1.50 diopters [D]), moderate (1.75-2.75 D) and high (≥3.00 D) astigmatism. RESULTS: In the newly diagnosed refractive amblyopes, there were no significant meridional anisotropies across all outcome measures, but the post hoc analysis demonstrated that C3 amplitude was significantly higher in those with low (P = 0.02) and moderate (P = 0.004) astigmatism compared to those with high astigmatism. Refractive amblyopes had poorer GA and C3 amplitudes compared to controls by approximately two lines on the logMAR chart (monocular: P = 0.013; binocular: P = 0.014) and approximately 6 µV (monocular: P = 0.009; binocular: P = 0.027), respectively. CONCLUSIONS: Deleterious effects of high astigmatism was evident in newly diagnosed refractive amblyopes, but the neural deficits do not seem to be orientation-specific for the stimulus parameters investigated.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Yap TP, Luu CD, Suttle C, et al. Effect of Stimulus Orientation on Visual Function in Children with Refractive Amblyopia. Invest Ophthalmol Vis Sci. 2020. PMID: 32392311. doi:10.1167/iovs.61.5.5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。