飞秒激光辅助白内障手术与超声乳化白内障手术的非劣效随机试验
FACT试验为多中心随机对照非劣效性研究,纳入785例年龄相关性白内障患者,比较飞秒激光辅助白内障手术(FLACS)与常规超声乳化白内障手术(PCS)。术后3个月,两组未矫正远视力(UDVA)平均差异为-0.01 logMAR(-0.05至0.03),非劣效界值为0.1 logMAR,FLACS不劣于PCS,两组在视力、患者报告健康及安全性结局上无显著差异。
要点
- 术后3个月FLACS组与PCS组UDVA平均差异-0.01 logMAR(-0.05至0.03),非劣效成立。
- PCS组发生2例后囊膜撕裂,FLACS组无,其余次要结局无显著差异。
核心结论
- 术后3个月FLACS在视力结局上不劣于常规PCS,两组视力、患者报告健康及安全性结局相当。
研究设计与样本
- 多中心随机对照非劣效性试验,在英国3家NHS医院开展,纳入785例年龄相关性白内障患者,1:1随机分为FLACS组392例和PCS组393例。
主要发现
- 术后3个月UDVA平均差异为-0.01 logMAR(-0.05至0.03),矫正远视力平均差异为-0.01 logMAR(95%CI -0.05至0.02)。
- PCS组发生2例后囊膜撕裂,FLACS组无,所有次要结局两组间无显著差异。
关键数值与推荐
- 非劣效界值为0.1 logMAR,主要结局为术后3个月研究眼UDVA。
临床怎么用
- FLACS可作为常规PCS的替代术式,两者术后3个月视力与安全性结局相当。
局限性
- 仅报告术后3个月结果,临床有效性与成本效果的长期结局尚待报告。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To report the 3-month results of a randomized trial (Femtosecond Laser-Assisted Cataract Trial [FACT]) comparing femtosecond laser-assisted cataract surgery (FLACS) with standard phacoemulsification cataract surgery (PCS). DESIGN: Multicenter, randomized controlled trial funded by the UK National Institute of Health Research (HTA 13/04/46/). PARTICIPANTS: Seven hundred eighty-five patients with age-related cataract. METHODS: This trial took place in 3 hospitals in the UK National Health Service (NHS). Randomization (1:1) was stratified by site, surgeon, and 1 or both eyes eligible using a secure web-based system. Postoperative assessments were masked to the allocated intervention. The primary outcome was unaided distance visual acuity (UDVA) in the study eye at 3 months. Secondary outcomes included corrected distance visual acuity, complications, and patient-reported outcomes measures. The noninferiority margin was 0.1 logarithm of the minimum angle of resolution (logMAR). ISRCTN.com registry, number ISRCTN77602616. MAIN OUTCOME MEASURES: We enrolled 785 participants between May 2015 and September 2017 and randomly assigned 392 to FLACS and 393 to PCS. At 3 months postoperatively, mean UDVA difference between treatment arms was -0.01 logMAR (-0.05 to 0.03), and mean corrected distance visual acuity difference was -0.01 logMAR (95% confidence interval [CI], -0.05 to 0.02). Seventy-one percent of both FLACS and PCS cases were within ±0.5 diopters (D) of the refractive target, and 93% of FLACS and 92% of PCS cases were within ±1.0 D. There were 2 posterior capsule tears in the PCS arm and none in the FLACS arm. There were no significant differences between arms for any secondary outcome. CONCLUSIONS: Femtosecond laser-assisted cataract surgery is not inferior to conventional PCS surgery 3 months after surgery. Both methods are as good in terms of vision, patient-reported health, and safety outcomes at 3 months. Longer-term outcomes of the clinical effectiveness and cost-effectiveness are awaited.
引用
- Day AC, Burr JM, Bennett K, et al. Femtosecond Laser-Assisted Cataract Surgery Versus Phacoemulsification Cataract Surgery (FACT): A Randomized Noninferiority Trial. Ophthalmology. 2020. PMID: 32386810. doi:10.1016/j.ophtha.2020.02.028
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。