文献速递眼底病与葡萄膜炎眼外伤

全充填玻璃体腔用黏性眼科黏弹剂辅助取出眼内异物

Total Filling of the Vitreous Cavity With a Cohesive Ophthalmic Viscosurgical Device to Support the Removal of the Intraocular Foreign Body.
PubMed 文献 · Retina · 2020-05-28

结果所有异物被抬升至玻璃体腔中央并安全夹取,术后3个月最佳矫正视力5例为20/20、2例为20/25,早期无眼压升高,无眼内炎发生。

要点

  • 完全充填黏性眼科黏弹剂可抬升并悬浮眼内异物,便于安全夹取。
  • 术后3个月最佳矫正视力5例20/20、2例20/25,早期无眼压升高。
  • 无患者发生眼内炎。

核心结论

  • 全充填玻璃体腔用黏性眼科黏弹剂是辅助后节眼内异物更可靠取出的有效手术选择。

研究设计与样本

  • 术中完全充填黏性眼科黏弹剂(Eyefill C或Bio-Hyalur Plus)后开始取出异物。
  • 在就诊时及术后1天、7天、1个月、3个月进行眼科检查,评估最佳矫正视力和眼压。

主要发现

  • 所有患眼异物均被抬升至玻璃体腔中央,悬浮于黏弹剂中可安全夹取并成功取出。
  • 术后3个月最佳矫正视力5例为20/20,2例为20/25。
  • 术后早期未发生眼压升高。
  • 无患者发生眼内炎。

临床怎么用

  • 后节眼内异物取出术中可考虑完全充填黏性眼科黏弹剂以抬升和悬浮异物,便于安全夹取。

局限性

  • 样本量为7例连续患者,非对照设计,随访至术后3个月。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the effectiveness of loading the vitreous cavity with a cohesive ophthalmic viscosurgical device in aiding the removal of the posterior segment intraocular foreign body (IOFB). METHODS: Seven consecutive patients underwent a small-gauge vitrectomy due to eye trauma with the IOFB between January 2019 and December 2019. The IOFB removal was initiated after total filling the vitreous cavity with the ophthalmic viscosurgical device (Eyefill C or Bio-Hyalur Plus) to facilitate maneuvering and slow the descent in cases of the unintendedly released IOFBs. The eye examination was performed at presentation and at 1 day, 7 days, 1 month, and 3 months after surgery. The best-corrected visual acuity and intraocular pressure were evaluated. RESULTS: In all eyes, IOFBs were elevated into the center of the vitreous cavity and could be securely gripped while suspended in the ophthalmic viscosurgical device to allow the surgeon for successful and harmless removal. In the 3-month follow-up, the best-corrected visual acuity was 20/20 in 5 patients and 20/25 in 2 patients. In the early postoperative period, the elevation of intraocular pressure did not occur. No patient developed endophthalmitis. CONCLUSION: The authors demonstrated that this uncomplicated technique is an effective surgical option for more reliable removal of posterior segment IOFBs.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Rogaczewska M, Stopa M. Total Filling of the Vitreous Cavity With a Cohesive Ophthalmic Viscosurgical Device to Support the Removal of the Intraocular Foreign Body. Retina. 2020. PMID: 32472826. doi:10.1097/IAE.0000000000002858

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。