文献速递眼底病与葡萄膜炎

扩展视野OCTA评估脉络膜黑色素瘤放疗后视网膜和脉络膜改变

EXTENDED FIELD IMAGING OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY FOR THE STUDY OF RETINAL AND CHOROIDAL CHANGES AFTER RADIATION THERAPY FOR CHOROIDAL MELANOMA: Comparison With Wide-Field Angiography.
PubMed 文献 · Retina · 2021-01-01

该横断面观察研究纳入20例脉络膜黑色素瘤放疗后视网膜病变患者,比较扩展视野OCTA(EFI-OCTA)与宽视野血管造影的成像范围及缺血区测量。结果显示EFI-OCTA视野大于无EFI的OCTA和55°镜头FA/ICGA,但小于102°镜头FA/ICGA;EFI-OCTA与55°镜头FA/ICGA测量的视网膜和脉络膜缺血面积无显著差异,提示EFI-OCTA可作为无创随访工具。

要点

  • EFI-OCTA视野平均扩展为无EFI OCTA的1.98倍,为55° FA/ICGA的1.21倍。
  • EFI-OCTA测量的视网膜和脉络膜无灌注区面积显著大于无EFI OCTA,但小于102° FA/ICGA。
  • EFI-OCTA与55° FA/ICGA测量的缺血面积无显著差异,视网膜和脉络膜血管密度与无灌注区呈负相关。

核心结论

  • EFI-OCTA可捕获比无EFI OCTA和55°镜头FA/ICGA更大的区域,清晰显示放疗后视网膜和脉络膜血管改变。
  • EFI-OCTA作为一种安全无创的成像技术,可能在辐射性视网膜病变患者随访中发挥作用。

研究设计与样本

  • 横断面观察研究,纳入20例脉络膜黑色素瘤放疗后视网膜病变患者的20只眼。
  • 所有患者接受FA和ICGA(55°和102°镜头)及Zeiss PlexElite 9000扫频源OCTA(12×12-mm扫描联合+20.00D透镜)的EFI检查。
  • 比较成像方法的可见视野、无灌注区范围和血管密度。

主要发现

  • EFI-OCTA相比无EFI OCTA、55° FA/ICGA和102° FA/ICGA的平均扩展比分别为1.98±0.02、1.21±0.01和0.36±0.003。
  • EFI-OCTA测量的视网膜和脉络膜无灌注区面积(63.03±48.21和38.63±30.83 mm²)显著高于无EFI OCTA(40.40±34.87和24.26±21.82 mm²,P<0.001),但低于102° FA/ICGA(140.7±69.23和108.3±69.51 mm²,P<0.001)。
  • EFI-OCTA与55° FA/ICGA测量的视网膜和脉络膜缺血面积(69.64±51.92和47.23±33.59 mm²)无显著差异。
  • EFI-OCTA的视网膜和脉络膜血管密度与无EFI OCTA相比有显著差异(P<0.05)。
  • EFI-OCTA测量的视网膜血管密度与视网膜无灌注区面积呈负相关(r=-0.5,P=0.02),脉络膜血管密度与脉络膜无灌注区面积呈负相关(r=-0.6,P=0.003)。

临床怎么用

  • EFI-OCTA可无创地评估放疗后视网膜和脉络膜无灌注区,其测量范围与55° FA/ICGA相当。
  • 在辐射性视网膜病变随访中,EFI-OCTA可能作为FA/ICGA的补充或替代成像手段。

局限性

  • 本研究为横断面观察研究,样本量较小(20只眼)。
  • EFI-OCTA的成像范围仍小于102°宽视野FA/ICGA。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Radiation retinopathy is a common side effect of ocular radiotherapy with no long-term effective therapy. Optical coherence tomography angiography (OCTA) and wide-field fluorescein angiography (FA) are widely used for the study of radiation maculopathy and peripheral nonperfusion, respectively. We investigated the role of extended field imaging (EFI-OCTA) for the study of retinal and choroidal alterations after radiotherapy for choroidal melanoma. METHODS: Cross-sectional observational study of 20 eyes of 20 patients diagnosed with radiation retinopathy. All patients underwent a complete imaging evaluation including FA and indocyanine green angiography (ICGA) with 55° and 102° lens (Spectralis Heidelberg Engineering, Heidelberg, Germany). Optical coherence tomography angiography imaging was performed with the Zeiss PlexElite 9000 Swept Source OCTA (Carl Zeiss Meditec, Dublin, CA) using a 12 × 12-mm volume scan pattern centered on the fovea and a +20.00-diopter lens specifically designed to obtain EFI examination. The imaging methods were then compared in terms of visible field of view, extension of nonperfused areas, and vessel density. RESULTS: The mean extension ratio of EFI-OCTA compared to OCTA without EFI, FA/ICGA 55° and FA/ICGA 102° was, respectively, 1.98 ± 0.02, 1.21 ± 0.01 and 0.36 ± 0.003. The mean extension of retinal and choroidal nonperfused areas evaluated by EFI-OCTA (63.03 ± 48.21 and 38.63 ± 30.83 mm2) were significantly higher than with OCTA without EFI (40.40 ± 34.87 and 24.26 ± 21.82 mm2, P < 0.001) but lower than with FA/ICGA 102° (140.7 ± 69.23 and 108.3 ± 69.51 mm2, P < 0.001). No significant differences were found between mean extension of retinal and choroidal ischemic areas measured with EFI-OCTA and FA/ICGA 55° (69.64 ± 51.92 and 47.23 ± 33.59 mm2). The mean vessel density of EFI-OCTA (retina and choroid segmentation) was significantly different compared to OCTA without EFI (P < 0.05). Retinal vessel density was negatively correlated to retinal extension of nonperfused areas (r = -0.5, P = 0.02), and choroidal vessel density was negatively correlated to choroidal nonperfused areas (r = -0.6, P = 0.003) measured with EFI-OCTA. CONCLUSION: In our series, EFI-OCTA captured larger areas than OCTA without EFI and FA/ICGA with 55° lens. EFI-OCTA images showed a good definition of retinal and choroidal vascular changes after radiotherapy, suggesting a possible role of this safe and noninvasive imaging technique in the follow-up of patients with radiation retinopathy.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Preziosa C, Corvi F, Staurenghi G, et al. EXTENDED FIELD IMAGING OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY FOR THE STUDY OF RETINAL AND CHOROIDAL CHANGES AFTER RADIATION THERAPY FOR CHOROIDAL MELANOMA: Comparison With Wide-Field Angiography. Retina. 2021. PMID: 32404848. doi:10.1097/IAE.0000000000002848

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。