硅油填充视网膜脱离术后逆行性黄斑病变相关的视力损害与黄斑血管重塑
PURPOSE: To assess the frequency of macular cysts (MCs) in retinal detachment treated with silicone oil and evaluate their impact on visual acuity and macular vascularization using optical coherence tomography-angiography.…
要点
- 硅油取出后黄斑囊肿(MC)发生率为58%,60%位于内核层。
- MC组BCVA低于非MC组(P=0.012),囊肿面积与BCVA负相关(P=0.0201)。
- MC组浅层毛细血管丛密度更高(P<0.0001),浅层中心凹无血管区面积更低(P<0.0001)。
核心结论
- 硅油取出后内核层黄斑囊肿发生率高,与视力损害和黄斑血管重塑相关,类似于逆行性黄斑病变现象。
主要发现
- MC组平均BCVA低于非MC组(P=0.012),黄斑囊肿面积与BCVA负相关(P=0.0201)。
- MC组浅层毛细血管丛密度高于非MC组(P<0.0001),浅层中心凹无血管区面积低于非MC组(P<0.0001)。
- 黄斑囊肿面积与深层毛细血管丛密度负相关(P<0.001)。
临床怎么用
- 硅油取出后应关注黄斑囊肿,尤其位于内核层者,可能提示视力预后不良和血管重塑。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To assess the frequency of macular cysts (MCs) in retinal detachment treated with silicone oil and evaluate their impact on visual acuity and macular vascularization using optical coherence tomography-angiography. METHODS: Forty-three eyes of 41 patients treated with silicone oil for retinal detachment were retrospectively studied. Best-corrected visual acuity and 6- × 6-mm optical coherence tomography-angiography examination at least 3 months after silicone oil removal were reviewed. In eyes with MCs, cyst area was measured on the en face optical coherence tomography-angiography image using ImageJ. Density of superficial capillary plexus and area of superficial foveal avascular zone were generated by the optical coherence tomography-angiography. Density of deep capillary plexus and deep foveal avascular zone area were measured using ImageJ. RESULTS: Twenty-five eyes (58%) presented with MCs. Cysts were exclusively located in the inner nuclear layer in 60% of cases. Mean best-corrected visual acuity in the MC group was lower than that of the non-MC group (P = 0.012). Macular cyst area negatively correlated with best-corrected visual acuity (P = 0.0201). Density of superficial capillary plexus was higher in the MC group (P < 0.0001), whereas area of superficial foveal avascular zone was lower (P < 0.0001). Macular cyst area negatively correlated with density of deep capillary plexus (P < 0.001). CONCLUSION: The incidence of INL-MCs after silicone oil removal is high. These are associated with impaired vision and macular vascular remodeling. We highlight their similarity with the "retrograde maculopathy" phenomenon.
引用
- Dormegny L, Jeanjean LC, Liu X, et al. VISUAL IMPAIRMENT AND MACULAR VASCULAR REMODELING SECONDARY TO RETROGRADE MACULOPATHY IN RETINAL DETACHMENT TREATED WITH SILICON OIL TAMPONADE. Retina. 2021. PMID: 32404843. doi:10.1097/IAE.0000000000002812
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。