早期与中期年龄相关性黄斑变性中脉络膜毛细血管血流与暗视微视野的相关性
前瞻性横断面研究纳入30眼早期或中期年龄相关性黄斑变性(AMD),用扫频源OCTA测量脉络膜毛细血管血流缺损百分比,暗适应30分钟后行暗视微视野检查。多变量回归显示中心10°平均敏感度(MS10)仅与3mm血流缺损(FD3mm)显著相关,整体18°敏感度(MS18)与6mm血流缺损(FD6mm)及视网膜下玻璃膜疣样沉积(SDD)显著相关。
要点
- 早期/中期AMD中脉络膜毛细血管血流缺损与暗视黄斑敏感度显著相关。
- 中心10°敏感度仅与FD3mm独立相关(β=-0.628,P<.001)。
- 整体18°敏感度与FD6mm(β=-0.473,P=.005)及SDD(β=-0.32,P=.047)相关。
核心结论
- 在早期或中期AMD眼中,脉络膜毛细血管血流受损与暗视黄斑敏感度存在显著相关性。
- 若未来纵向研究重复验证,脉络膜毛细血管血流缺损百分比可能成为评估此类眼功能状态与预后的有用参数。
研究设计与样本
- 前瞻性横断面研究,纳入连续早期或中期AMD患者30例30眼,于Doheny UCLA Eye Centers完成。
- 每眼采集2幅3×3 mm和2幅6×6 mm扫频源OCTA图像,信号丢失补偿后取平均。
- 暗适应30分钟后行暗视微视野检查,采用以黄斑中心凹为中心、覆盖18°范围的52个刺激点网格。
主要发现
- 30眼中14眼(46.7%)存在视网膜下玻璃膜疣样沉积(SDD)。
- 平均OCTA扫描中FD3mm为12.56%±2.41%,FD6mm为9.33%±1.84%。
- 平均MS10为13.84±5.89 dB,MS18为14.64±5.21 dB。
- 多变量回归分析中,MS10仅与FD3mm显著相关(β:-0.628,P<.001)。
- MS18与SDD(β:-0.32,P=.047)及FD6mm(β:-0.473,P=.005)均显著相关。
关键数值与推荐
- 多变量回归显示MS10与FD3mm显著相关(β:-0.628,P<.001)。
- MS18与SDD显著相关(β:-0.32,P=.047),与FD6mm显著相关(β:-0.473,P=.005)。
- 研究眼FD3mm均值12.56%±2.41%,FD6mm均值9.33%±1.84%。
- 研究眼MS10均值13.84±5.89 dB,MS18均值14.64±5.21 dB。
临床怎么用
- 对早期或中期AMD患者,可结合OCTA测量的脉络膜毛细血管血流缺损百分比与暗视微视野敏感度评估功能状态。
- 中心10°暗视敏感度下降时,可关注3mm扫描范围内脉络膜毛细血管血流缺损。
- 整体18°暗视敏感度下降时,可同时关注6mm扫描范围血流缺损及SDD的存在。
局限性
- 研究为横断面设计,无法确立因果关系。
- 样本量为30眼,结论需未来纵向研究重复验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the correlation between choriocapillaris (CC) flow alterations and scotopic macular sensitivity (sMS) in patients with early and intermediate age-related macular degeneration (AMD). DESIGN: Prospective cross-sectional study. METHODS: We acquired 2 3 × 3 mm and 2 6 × 6 mm swept-source optical coherence tomography angiography (OCTA) images of 1 eye of consecutive early or intermediate AMD patients at the Doheny UCLA Eye Centers. After 30 minutes of dark adaptation, the same eye underwent scotopic microperimetry with an 18-degree-wide grid (52 stimuli) centered on the fovea. The 2 en face CC angiograms obtained from each scan pattern were compensated for signal loss and averaged. The main outcome measures were correlation between percentages of flow deficits (FD3mm and FD6mm) and sMS in the central 10° (MS10) and the overall pattern (MS18). RESULTS: Thirty eyes of 30 patients were enrolled, with 14 (46.7%) having subretinal drusenoid deposits (SDD). In the averaged OCTA scans, the FD3mm was 12.56% ± 2.41% while the FD6mm was 9.33% ± 1.84%. The mean MS10 and MS18 were 13.84 ± 5.89 dB and 14.64 ± 5.21 dB, respectively. For the MS10, the multivariate regression analysis showed a significant association only with FD3mm (β: -0.628, P < .001) while the MS18 was significantly correlated with both SDD (β: -0.32, P = .047) and FD6mm (β: -0.473, P = .005). CONCLUSIONS: Our study reports a significant correlation between the CC flow impairment and the sMS in eyes with early or intermediate AMD. If replicated in future longitudinal studies, the choriocapillaris FD may prove to be a useful parameter for evaluating the functional status and prognosis of these eyes.
引用
- Nassisi M, Tepelus T, Corradetti G, et al. Relationship Between Choriocapillaris Flow and Scotopic Microperimetry in Early and Intermediate Age-related Macular Degeneration. Am J Ophthalmol. 2020. PMID: 32360341. doi:10.1016/j.ajo.2020.04.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。