文献速递眼底病与葡萄膜炎

智能手机眼底成像在印度糖尿病视网膜病变筛查中的评估

Diabetic Retinopathy Screening Using Smartphone-Based Fundus Imaging in India.
PubMed 文献 · Ophthalmology · 2020-05-25

该研究在南印度外展眼科诊所纳入193例糖尿病患者的381只眼,比较4种技术不同的智能手机眼底成像(SBFI)方式对糖尿病视网膜病变(DR)筛查的图像质量与诊断准确性。基于间接检眼镜的SBFI图像质量最佳(P<0.01)、视野最大,与参考标准一致性(Cohen's kappa 0.868)及对重度DR的敏感度/特异度(1.0/1.0)最高。结论认为SBFI可满足外展场景DR筛查要求,但并非所有设备在图像质量和诊断准确性上均适用。

要点

  • 基于间接检眼镜的SBFI图像质量最佳、视野最大,检查时间最长(111秒 vs 68-86秒,P<0.0001)。
  • 该方式与参考标准一致性Cohen's kappa为0.868,检出重度DR的敏感度/特异度均为1.0。
  • SBFI可满足外展DR筛查要求,但设备选择需考虑图像质量与诊断准确性。

核心结论

  • 基于间接检眼镜的SBFI在图像质量、视野和DR诊断准确性上表现最佳,SBFI可满足外展场景的DR筛查要求,但并非所有设备均适用。

研究设计与样本

  • 诊断技术评估研究,在南印度外展眼科诊所招募193例糖尿病患者的381只眼。
  • 比较4种技术不同的SBFI方式(3种基于直接检眼镜、1种基于间接检眼镜),对照传统眼底照相与临床检查。

主要发现

  • 基于间接检眼镜的SBFI图像质量最佳(P<0.01),视野最大,检查时间最长(111秒 vs 68-86秒,P<0.0001)。
  • 该方式与参考标准的一致性Cohen's kappa为0.868,检出任何DR的敏感度/特异度为0.79/0.99。
  • 检出重度DR的敏感度/特异度为1.0/1.0,检出糖尿病性黄斑病变为0.79/1.0。

关键数值与推荐

  • 检查时间:间接SBFI为111秒,其他方式为68-86秒(P<0.0001)。
  • 与参考标准一致性:Cohen's kappa 0.868(间接SBFI)。
  • 诊断准确性:任何DR敏感度/特异度0.79/0.99,重度DR 1.0/1.0,糖尿病性黄斑病变0.79/1.0。

临床怎么用

  • 在低收入和中等收入国家的外展筛查中,可优先选择基于间接检眼镜的SBFI设备以兼顾图像质量与诊断准确性。
  • 现场试验中筛选SBFI设备时应评估图像质量、视野与诊断准确性,而非默认所有设备适用。

局限性

  • 原文未报告局限性相关内容。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Early detection and treatment can prevent irreversible blindness from diabetic retinopathy (DR), which is the leading cause of visual impairment among working-aged adults worldwide. Some 80% of affected persons live in low- and middle-income countries, yet lack of resources has largely prevented DR screening implementation in these world regions. Smartphone-based fundus imaging (SBFI) allows for low-cost mobile fundus examination using an adapter on a smartphone; however, key aspects such as image quality, diagnostic accuracy, and comparability of different approaches have not been systematically assessed to date. DESIGN: Evaluation of diagnostic technology. PARTICIPANTS: A total of 381 eyes of 193 patients with diabetes were recruited at outreach eye clinics in South India. METHODS: We compared 4 technically different approaches of SBFI (3 approaches based on direct and 1 approach based on indirect ophthalmoscopy) in terms of image quality and diagnostic accuracy for DR screening. MAIN OUTCOME MEASURES: Image quality (sharpness/focus, reflex artifacts, contrast, and illumination), field-of-view, examination time, and diagnostic accuracy for DR screening were analyzed against conventional fundus photography and clinical examination. RESULTS: Smartphone-based fundus imaging based on indirect ophthalmoscopy yielded the best image quality (P < 0.01), the largest field-of-view, and the longest examination time (111 vs. 68-86 seconds, P < 0.0001). Agreement with the reference standard (Cohen's kappa 0.868) and sensitivity/specificity to detect DR were highest for the indirect SBFI approach (0.79/0.99 for any DR and 1.0/1.0 for severe DR, 0.79/1.0 for diabetic maculopathy). CONCLUSIONS: Smartphone-based fundus imaging can meet DR screening requirements in an outreach setting; however, not all devices are suitable in terms of image quality and diagnostic accuracy. Smartphone-based fundus imaging might aid in alleviating the burden of DR screening in low- and middle-income countries, and these results will allow for a better selection of SBFI devices in field trials for DR screening.

来源:Ophthalmology,查看原文。版权归原作者所有。

引用

  1. Wintergerst MWM, Mishra DK, Hartmann L, et al. Diabetic Retinopathy Screening Using Smartphone-Based Fundus Imaging in India. Ophthalmology. 2020. PMID: 32464129. doi:10.1016/j.ophtha.2020.05.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。