这项回顾性多中心横断面研究纳入2017年4月至2019年3月国际ODDS联盟神经眼科门诊中50岁及以下的NA-AION患者,评估视盘玻璃膜疣(ODD)的患病率。65例患者(127眼)中,74只NA-AION眼中51%合并ODD(ODD-AION),而无NA-AION的对侧眼43%有ODD(P = .36);ODD-AION与NODD-AION在最佳矫正视力或视野平均偏差上无显著差异。作者认为ODD可能是年轻患者发生NA-AION的独立危险因素,并建议将ODD-AION作为一种新诊断加以认识。
要点
- 年轻NA-AION患者中约半数患眼合并ODD,提示ODD可能是其独立危险因素。
- ODD-AION与NODD-AION的最佳矫正视力和视野平均偏差无显著差异。
- EDI-OCT显示ODD-AION眼PHOMS和强反射线比例均高于NODD-AION眼。
核心结论
- 多数年轻NA-AION患者合并ODD,提示ODD至少在该人群中可能是NA-AION发生的独立危险因素。
- 研究建议将合并ODD的NA-AION(ODD-AION)作为一种新的诊断加以认识。
研究设计与样本
- 回顾性、横断面多中心研究,纳入2017年4月1日至2019年3月31日国际ODDS联盟神经眼科门诊的50岁及以下NA-AION患者。
- 共纳入65例患者(127眼),平均年龄41岁;ODD经任何方法诊断或按ODDS联盟指南用EDI-OCT排除。
- NA-AION眼中合并ODD者称ODD-AION,未合并者称NODD-AION。
主要发现
- 74只NA-AION眼中51%为ODD-AION,而无NA-AION的对侧眼中43%有ODD(P = .36)。
- ODD-AION与NODD-AION眼在Snellen最佳矫正视力或视野平均偏差上无显著差异。
- 按EDI-OCT结果,NODD-AION眼中28%有PHOMS、7%有强反射线,ODD-AION眼中54%有PHOMS、66%有强反射线(分别为P = .006和P < .001)。
关键数值与推荐
- ODD在一般人群中的存在比例为2%。
- NA-AION患者年龄限定为50岁及以下。
- ODD-AION与NODD-AION的PHOMS比例比较P = .006,强反射线比例比较P < .001。
临床怎么用
- 对50岁及以下的NA-AION患者,应通过EDI-OCT等检查评估是否合并ODD。
- 识别ODD有助于将此类病例归为ODD-AION并重新评估其风险与随访策略。
局限性
- 原文摘要未报告研究的局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Optic disc drusen (ODD), present in 2% of the general population, have occasionally been reported in patients with nonarteritic anterior ischemic optic neuropathy (NA-AION). The purpose of this study was to examine the prevalence of ODD in young patients with NA-AION. DESIGN: Retrospective, cross-sectional multicenter study. METHODS: All patients with NA-AION 50 years old or younger, seen in neuro-ophthalmology clinics of the international ODDS (Optic Disc Drusen Studies) Consortium between April 1, 2017, and March 31, 2019, were identified. Patients were included if ODD were diagnosed by any method, or if ODD were excluded by enhanced-depth imaging optical coherence tomography (EDI-OCT) using ODDS Consortium guidelines. NA-AION eyes with ODD were termed "ODD-AION"; those without were termed "NODD-AION". RESULTS: A total of 65 patients (127 eyes) with NA-AION were included (mean 41 years old). Of the 74 eyes with NA-AION, 51% had ODD-AION, whereas 43% of fellow eyes without NA-AION had ODD (P = .36). No significant differences were found between ODD-AION and NODD-AION eyes in terms of Snellen best-corrected VA or perimetric mean deviation. According to EDI-OCT results, 28% of eyes with NODD-AION had peripapillary hyperreflective ovoid mass-like structures (PHOMS); 7% had hyperreflective lines, whereas 54% with ODD-AION had PHOMS; and 66% had hyperreflective lines (P = .006 and P < .001, respectively). CONCLUSIONS: Most of these young NA-AION patients had ODD. This indicates that ODD may be an independent risk factor for the development of NA-AION, at least in younger patients. This study suggests ODD-AION be recognized as a novel diagnosis.