文献速递白内障与屈光手术眼外伤

扫频源OCT与超声生物显微镜评估外伤性白内障后囊膜的准确性

Accuracy of Swept-Source Optical Coherence Tomography and Ultrasound Biomicroscopy for Evaluation of Posterior Lens Capsule in Traumatic Cataract.
PubMed 文献 · Am J Ophthalmol · 2020-04-02

本研究纳入67例因外伤性白内障遮挡而无法裂隙灯评估后囊膜的患者,分别用50MHz UBM和SS-OCT评估后囊膜缺损,再行单一术式白内障手术。SS-OCT的敏感度96.8%、特异度66.7%、准确率82%,UBM分别为82.6%、57.9%、71.4%;作者推荐外伤性白内障术前用SS-OCT评估后囊膜。

要点

  • SS-OCT检测外伤性白内障后囊膜缺损的敏感度为96.8%,特异度为66.7%。
  • UBM检测后囊膜缺损的敏感度为82.6%,特异度为57.9%。
  • SS-OCT阴性预测值95.2%,有助于排除后囊膜破裂。

核心结论

  • SS-OCT与UBM均能有效检测外伤性白内障术前后囊膜破裂,SS-OCT至少与UBM相当,在特殊情况下可能更优。
  • 作者推荐所有外伤性白内障术前使用SS-OCT评估后囊膜,作为手术规划的一部分。

研究设计与样本

  • 观察性病例系列,纳入67例(67眼)因外伤性白内障严重遮挡而无法裂隙灯评估后囊膜的患者。
  • 患者按简单序列(非随机)分别由不同操作者行50MHz UBM和SS-OCT评估后囊膜,随后以单一技术行白内障手术。

主要发现

  • SS-OCT检测后囊膜缺损的敏感度96.8%(95%CI 83.81-99.43)、特异度66.7%(95%CI 48.78-80.77)、准确率82%(95%CI 70.53-89.62)。
  • UBM检测后囊膜缺损的敏感度82.6%(95%CI 62.86-93.02)、特异度57.9%(95%CI 36.28-76.86)、准确率71.4%(95%CI 56.43-82.83)。
  • SS-OCT阳性预测值75%(95%CI 59.81-85.81)、阴性预测值95.2%(95%CI 77.33-99.15);UBM阳性预测值70.4%(95%CI 51.52-84.15)、阴性预测值73.3%(95%CI 48.05-89.1)。

关键数值与推荐

  • SS-OCT敏感度96.8%、特异度66.7%、准确率82%、阳性预测值75%、阴性预测值95.2%。
  • UBM敏感度82.6%、特异度57.9%、准确率71.4%、阳性预测值70.4%、阴性预测值73.3%。

临床怎么用

  • 对裂隙灯无法评估后囊膜的外伤性白内障,术前可用SS-OCT评估后囊膜缺损以辅助手术规划。
  • SS-OCT阴性预测值较高,阴性结果对排除后囊膜破裂有较高参考价值。

局限性

  • 原文未报告局限性相关内容。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess the efficacy of swept-source optical coherence tomography (SS-OCT) and ultrasound biomicroscopy (UBM) in detecting posterior capsule (PC) defect in patients with traumatic cataract. DESIGN: Observational case-series. METHODS: Sixty-seven eyes from 67 patients, with traumatic cataract severe enough to prevent slit lamp evaluation of the PC, were included in a simple sequence without randomization. Patients underwent both 50-MHz UBM and SS-OCT evaluation of the PC by different operators. Cataract surgery was then performed using a single technique. RESULTS: Sixty-seven eyes from 67 patients including 60 men and 7 women were studied. The mean age was 34 ± 14 years and the mean logarithm of minimal angle of resolution of visual acuity was 1.89 ± 0.71. The calculated sensitivity, specificity, and accuracy values for SS-OCT were 96.8% (95% confidence interval [CI] 83.81-99.43), 66.7% (95% CI 48.78-80.77), and 82% (95% CI 70.53-89.62), respectively. For UBM, sensitivity, specificity, and accuracy values were 82.6% (95% CI 62.86-93.02), 57.9% (95% CI 36.28-76.86), and 71.4% (95% CI 56.43-82.83), respectively. Positive predictive and negative predictive values for SS-OCT were 75% (95% CI 59.81-85.81) and 95.2% (95% CI 77.33-99.15) and for UBM were 70.4% (95% CI 51.52-84.15) and 73.3% (95% CI 48.05-89.1), respectively. CONCLUSION: Although both imaging techniques are effective, SS-OCT appears to be at least comparable, or superior in special circumstances, to UBM in detecting preoperative posttraumatic PC rupture. We recommend preoperative assessment of all traumatic cataracts with SS-OCT as a part of surgical planning.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Tabatabaei SA, Soleimani M, Etesali H, et al. Accuracy of Swept-Source Optical Coherence Tomography and Ultrasound Biomicroscopy for Evaluation of Posterior Lens Capsule in Traumatic Cataract. Am J Ophthalmol. 2020. PMID: 32247777. doi:10.1016/j.ajo.2020.03.030

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。