10-2标准自动视野计检测进展:基于事件算法的开发与验证
本研究开发了一种基于事件分析的10-2视野进展检测算法,并在独立青光眼队列中验证。验证队列平均随访2.3年,「可能进展」和「很可能进展」分别占54.5%和16.6%,且与更快的MD下降相关。
要点
- 10-2视野事件算法可识别MD下降更快的青光眼眼。
- 「可能进展」标准:至少3个进展位点连续2次或3次测试。
- 验证队列中「很可能进展」眼MD年下降-0.91 dB。
核心结论
- 基于10-2视野的事件进展算法可识别MD进展更快的青光眼眼,可能用于评估黄斑功能进行性改变。
研究设计与样本
- 前瞻性队列研究,开发队列来自MAPS(n=151),验证队列来自ADAGES(n=52)。
- MAPS在4个月内完成4次重测;ADAGES使用至少5次访视的10-2视野结果。
主要发现
- 验证队列平均随访2.3年(SD 0.7)。
- 「可能进展」眼36只(54.5%),「很可能进展」眼11只(16.6%)。
关键数值与推荐
- 进展标准:至少3个进展视野位点在连续2次或3次测试中出现,分别定义为「可能进展」或「很可能进展」。
临床怎么用
- 可利用10-2视野事件算法辅助评估青光眼患者黄斑功能区进展。
局限性
- 验证队列样本量较小(n=52),随访时间较短(平均2.3年)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To describe the development of a new algorithm for detecting progressive changes in 10-2 visual field (VF) tests using event-based analysis and to test its validity in a second, independent glaucoma cohort. DESIGN: Prospective cohort study. METHODS: Patients with established open-angle glaucoma from the Macular Assessment and Progression Study (MAPS; development cohort, n = 151), and the African Descent and Glaucoma Evaluation Study (ADAGES; validation cohort, n = 52) were evaluated. The 10-2 VF results from MAPS were obtained during 4 test-retest sessions within a 4-month period. For the validation analysis, 10-2 VF results from ADAGES performed on at least 5 visits were used. The event-based pointwise changes on 10-2 tests in the validation cohort were determined using 2 progression criteria: at least 3 progressing VF locations on 2 or 3 consecutive tests ("possible" or "likely" progression). Linear mixed-effects models were used to evaluate VF progression. RESULTS: In the validation cohort, the mean (SD) follow-up time was 2.3 (0.7) years. The number of eyes experiencing 10-2 VF progression based on "possible" and "likely" progression was 36 (54.5%) and 11 (16.6%), respectively. Eyes experiencing "possible" progression had MD changes (-0.60 dB/year [95% confidence interval (CI): -0.93 to -0.28]) faster than those not meeting this criterion (P < .001), whereas for those with "likely" progression the difference was -0.91 dB/year (95% CI: -1.26 to -0.56, P < .001). CONCLUSIONS: A new event-based progression algorithm using the 10-2 VF can identify eyes experiencing more rapid MD progression and may be used as a tool to assess progressive macular functional changes in glaucoma.
引用
- De Moraes CG, Paula JS, Blumberg DM, et al. Detection of Progression With 10-2 Standard Automated Perimetry: Development and Validation of an Event-Based Algorithm. Am J Ophthalmol. 2020. PMID: 32278773. doi:10.1016/j.ajo.2020.03.046
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。