青光眼对人筛板压力诱导应变反应的影响
该离体研究对8例确诊青光眼供者16眼与6例无青光眼史供者10眼的后巩膜行5至45 mmHg充气测试,并用二次谐波成像与体积相关分析计算筛板应变。结果显示青光眼眼筛板压力-应变反应更硬,且随轴突损伤程度变化;轻度损伤眼筛板应变较低,重度损伤眼筛板应变较大且周边与中央最大主应变比值升高。
要点
- 青光眼眼筛板在10与45 mmHg下鼻颞向与环向应变较低,提示压力-应变反应更硬。
- 轴突丢失<25%的青光眼眼筛板应变小于未损伤正常眼,可能为基线生物力学行为。
- 轴突丢失>25%的青光眼眼周边与中央最大主应变比值更大,可能与青光眼相关重塑有关。
核心结论
- 确诊青光眼眼的筛板压力-应变反应更硬,并随青光眼性轴突损伤程度而变化。
- 轻度损伤眼筛板应变较低可能代表促成轴突丢失的基线生物力学行为。
- 重度损伤眼筛板应变较大及径向应变变异改变可能由青光眼相关重塑所致。
研究设计与样本
- 离体充气测试研究,纳入8例确诊青光眼供者的16眼与6例无青光眼史供者的10眼,压力范围5至45 mmHg。
- 对每例供者视神经检查轴突丢失程度,并用二次谐波成像后筛板后部体积并以体积相关分析计算5至10与5至45 mmHg间筛板应变。
主要发现
- 确诊青光眼眼的眼长与筛板面积更大(P ≤ 0.03)。
- 确诊青光眼眼筛板鼻颞向EXX与环向Eθθ应变在10 mmHg较低(P ≤ 0.05),在45 mmHg也较低(P ≤ 0.07)。
- 轴突丢失<25%的青光眼眼筛板EXX小于未损伤正常眼(P = 0.01,45 mmHg)。
- 总体上筛板周边应变大于中央。
- 轴突丢失>25%的青光眼眼周边与中央最大主应变Emax比值大于损伤较轻的青光眼眼(P = 0.004,10 mmHg)。
临床怎么用
- 解读青光眼筛板生物力学时需考虑损伤程度,轻度与重度损伤眼应变模式不同。
- 筛板应变较低与周边-中央应变比值升高或可作为区分损伤阶段的生物力学线索。
局限性
- 离体充气测试结果不能直接等同于在体眼内环境。
- 样本来自供者眼,青光眼眼与正常眼数量有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To measure the ex vivo pressure-induced strain response of the human optic nerve head and analyze for variations with glaucoma diagnosis and optic nerve axon damage. METHODS: The posterior sclera of 16 eyes from 8 diagnosed glaucoma donors and 10 eyes from 6 donors with no history of glaucoma were inflation tested between 5 and 45 mm Hg. The optic nerve from each donor was examined for degree of axon loss. The posterior volume of the lamina cribrosa (LC) was imaged with second harmonic generation and analyzed using volume correlation to calculate LC strains between 5 and 10 and 5 and 45 mm Hg. RESULTS: Eye length and LC area were larger in eyes diagnosed with glaucoma (P ≤ 0.03). Nasal-temporal EXX and circumferential Eθθ strains were lower in the LC of diagnosed glaucoma eyes at 10 mm Hg (P ≤ 0.05) and 45 mm Hg (P ≤ 0.07). EXX was smaller in the LC of glaucoma eyes with <25% axon loss compared with undamaged normal eyes (P = 0.01, 45 mm Hg). In general, the strains were larger in the peripheral than central LC. The ratio of the maximum principal strain Emax in the peripheral to central LC was larger in glaucoma eyes with >25% axon loss than in glaucoma eyes with milder damage (P = 0.004, 10 mm Hg). CONCLUSIONS: The stiffness of the LC pressure-strain response was greater in diagnosed glaucoma eyes and varied with glaucomatous axon damage. Lower LC strains in glaucoma eyes with milder damage may represent baseline biomechanical behavior that contributes to axon loss, whereas greater LC strain and altered radial LC strain variation in glaucoma eyes with more severe damage may be caused by glaucoma-related remodeling.
引用
- Midgett D, Liu B, Ling YTT, et al. The Effects of Glaucoma on the Pressure-Induced Strain Response of the Human Lamina Cribrosa. Invest Ophthalmol Vis Sci. 2020. PMID: 32343781. doi:10.1167/iovs.61.4.41
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。