巩膜扣带术后角膜生物力学响应改变
回顾性配对队列研究纳入18例单眼巩膜扣带术治疗孔源性视网膜脱离患者,比较术眼与对侧眼角膜生物力学。术眼角膜滞后和角膜阻力因子显著低于对侧眼,且Goldmann眼压显著低于角膜补偿眼压,提示巩膜扣带术影响角膜生物力学并可能影响眼压测量准确性。
要点
- 巩膜扣带术后术眼角膜滞后和角膜阻力因子显著低于对侧眼。
- 术眼Goldmann眼压显著低于角膜补偿眼压,对侧眼无此差异。
- 巩膜扣带术可能通过限制角膜运动影响眼压测量准确性。
核心结论
- 巩膜扣带术治疗孔源性视网膜脱离影响角膜生物力学响应,可能因巩膜顺应性降低限制角膜运动并减少能量耗散,表现为角膜滞后降低。
- 术眼眼压测量准确性可能受影响。
研究设计与样本
- 回顾性、对侧眼匹配的队列研究,纳入18例连续患者(11男7女),单眼因孔源性视网膜脱离行巩膜扣带术。
主要发现
- 术眼角膜滞后显著低于对侧眼(9.0 ± 1.8 vs 10.1 ± 1.8 mm Hg,P < .001)。
- 术眼角膜阻力因子显著低于对侧眼(10.0 ± 2.2 vs 10.9 ± 2.2 mm Hg,P < .001)。
- 术眼Goldmann眼压显著低于角膜补偿眼压(18.1 ± 4.9 vs 19.8 ± 4.8 mm Hg,P = .022),对侧眼无此差异。
- 术眼第二次压平事件(A2)发生更早,A2期间角膜运动速度更快。
临床怎么用
- 巩膜扣带术后术眼角膜生物力学改变可能影响眼压测量准确性,临床解读眼压时需考虑此因素。
局限性
- 原文未明确报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare the corneal biomechanics of eyes that underwent scleral buckle (SB) for rhegmatogenous retinal detachment (RRD) with those of fellow eyes (fellow eyes) and to further investigate the effects of SB on intraocular pressure (IOP) values. DESIGN: Retrospective, fellow-eye matched cohort study. METHODS: A total of 18 consecutive patients (11 males and 7 females) treated with SB for RRD in 1 eye were enrolled. Goldmann applanation tonometry was used to measure IOP. Biomechanical properties of the cornea were investigated by using the Ocular Response Analyzer (ORA) (Reichert Instruments) for the calculation of corneal resistant factor (CRF), corneal hysteresis, Goldmann-correlated IOP, and corneal-compensated IOP. Customized software was used for analysis of the ORA infrared and pressure signals, and a significance threshold was set to a P value of .05. RESULTS: Operated eyes (OEs) showed significantly lower values of corneal hysteresis and CRF than fellow eyes (9.0 ± 1.8 vs 10.1 ± 1.8 mm Hg, respectively; P < .001; 10.0 ± 2.2 vs 10.9 ± 2.2 mm Hg; P < .001). GAT was significantly lower than corneal-compensated IOP in OEs (18.1 ± 4.9 vs 19.8 ± 4.8 mm Hg, respectively; P = .022) but not in fellow eyes. The second applanation event (A2) took place earlier in time, and the cornea was moving faster during A2 in the OEs than in the fellow eyes. CONCLUSIONS: SB for the treatment of RRD affects corneal biomechanical response, likely due to a less compliant sclera that limits corneal motion and reduces energy dissipation, reflected in a lower corneal hysteresis. This has potentially meaningful clinical implications as the accuracy of the measurement of IOP values may be affected in these eyes.
引用
- Taroni L, Bernabei F, Pellegrini M, et al. Corneal Biomechanical Response Alteration After Scleral Buckling Surgery for Rhegmatogenous Retinal Detachment. Am J Ophthalmol. 2020. PMID: 32283097. doi:10.1016/j.ajo.2020.03.054
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。