糖尿病及糖尿病视网膜病变中的脉络膜厚度:扫频源OCT研究
研究纳入1347例中国2型糖尿病患者,用扫频源OCT测量脉络膜厚度(CT),按英国国家糖尿病眼病筛查指南分级DR。发现早期DR阶段CT增厚,随DR进展至R3阶段CT显著变薄;DME和HbA1c水平未显著影响平均CT;平均CT较高与更好BCVA显著相关。
要点
- 早期DR阶段脉络膜厚度增加,随DR进展至R3阶段显著变薄。
- 糖尿病黄斑水肿(DME)存在与否及HbA1c水平未显著影响平均CT。
- 平均CT每增加100µm,BCVA LogMAR降低0.02,与更好视力相关。
核心结论
- CT在DR早期阶段增加,随DR进展进一步下降;DME与CT无显著关联,提示脉络膜改变可能参与DR发病机制。
研究设计与样本
- 从中国广州社区卫生系统招募无眼部治疗史的2型糖尿病患者,使用扫频源OCT获取视网膜和脉络膜高清图像,按英国国家糖尿病眼病筛查指南分级DR,采用单因素和多因素线性回归分析。
- 最终分析纳入1347例患者。
主要发现
- 校正其他因素后,R3期DR患者CT较R0期显著变薄(β=-29.1 µm,95%CI -53.8至-4.4,P=0.021)。
- 校正其他因素后,部分象限CT较R0期增厚:鼻外侧15.6 µm(95%CI 4.3-26.9,P=0.007)、下外侧15.7 µm(95%CI 3.8-25.5,P=0.008)、下内侧12.2 µm(95%CI 0.4-24.0,P=0.042)。
- DME存在及HbA1c水平未显著影响平均CT。
- 平均CT较高与更好BCVA显著相关,平均CT每增加100 µm,LogMAR降低0.02(95%CI -0.03至-0.01,P<0.001)。
临床怎么用
- 临床评估DR患者时可关注脉络膜厚度变化,早期DR可能出现CT增厚,进展期变薄。
- DME存在与否不显著影响平均CT,CT不能替代DME评估。
- 较高平均CT与更好BCVA相关,或可作为视力预后的参考指标。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Previous studies on the association between choroidal thickness (CT) and severity of diabetic retinopathy (DR) gave conflicting results. The aim of this study was to evaluate the CT changes in diabetic patients and associated factors in a large sample of Chinese patients with diabetes. METHODS: Type 2 diabetes mellitus patients without history of ocular treatment were recruited from the community health system in Guangzhou, China. The swept source OCT instrument was used to obtain high-definition retina and choroid images. The diabetic retinopathy (DR) status was graded based on the guidelines of the United Kingdom National Diabetic Eye Screening Programme. Univariate and multivariate linear regression analyses was used to explore the association of CT with DR severity, diabetic macular edema (DME), hemoglobin A1c, and vision function. RESULTS: A total of 1347 patients were included in the final analysis. After adjusting for other factors, the patients with stage R3 DR had significantly thinner CT (β = -29.1 µm, 95% CI -53.8 to -4.4, P = 0.021) in comparison in those with R0. After adjusting for other factors, the CTs were thicker than those in R0 patients with difference of 15.6 µm (95% CI 4.3-26.9, P = 0.007) for outer nasal sector, 15.7 µm (95% CI 3.8-25.5, P = 0.008) for outer inferior, and 12.2 µm (95% CI 0.4-24.0, P = 0.042) for inner inferior sector. The presence of DME and hemoglobin A1c levels did not significantly affect average CT. Higher average CT was significantly associated with better best corrected visual acuity, with a -0.02 LogMAR unit per 100 µm increase in average CT (95% CI -0.03 to -0.01, P < 0.001). CONCLUSIONS: CT increased in the early stage of DR, and further decreased with DR progression. DME was not significantly associated with CT. These findings provide more clues to suggest that choroid alterations play a role in the pathogenesis of DR.
引用
- Wang W, Liu S, Qiu Z, et al. Choroidal Thickness in Diabetes and Diabetic Retinopathy: A Swept Source OCT Study. Invest Ophthalmol Vis Sci. 2020. PMID: 32324858. doi:10.1167/iovs.61.4.29
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。