基于自动验光仪参数构建圆锥角膜筛查指数的多中心研究
在日本5个中心纳入123例Amsler-Krumeich 1期圆锥角膜患者(平均26.36±8.68岁)和205例健康受试者(平均26.20±7.34岁),按2:1分为预测组和应用组。以自动验光仪参数进行多因素logistic回归建立圆锥角膜指数,ROC曲线下面积0.90,应用组敏感度85.0%、特异度86.7%。
要点
- 自动验光仪参数构建的圆锥角膜指数AUC为0.90,优于单一参数。
- 应用组敏感度85.0%、特异度86.7%,可辅助筛查早期圆锥角膜。
- 陡峭K值、平坦K值及顺规散光为入选解释变量。
核心结论
- 基于自动验光仪参数的新预测方程对早期圆锥角膜的判别能力优于单一参数,但敏感度与特异度不高。
研究设计与样本
- 日本5个中心的多中心研究,纳入123眼123例Amsler-Krumeich 1期圆锥角膜患者和205眼205例健康受试者,按2:1分为预测组和应用组。
主要发现
- 入选解释变量为陡峭K值(β 1.284,OR 3.610)、平坦K值(β -0.618,OR 0.539)和顺规散光(β -3.163,OR 0.042)。
- 圆锥角膜指数的ROC曲线下面积为0.90,显著优于单一参数(P < .001)。
- 应用组敏感度为85.0%,特异度为86.7%。
关键数值与推荐
- 圆锥角膜指数截断值由ROC曲线确定。
- 预测方程在应用组中敏感度85.0%、特异度86.7%。
临床怎么用
- 可利用自动验光仪参数计算圆锥角膜指数,辅助筛查早期圆锥角膜。
局限性
- 原文指出敏感度与特异度不高。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Screening of early-stage keratoconus using auto-keratometer parameters. DESIGN: Evaluation of a screening approach. METHODS: At 5 major centers in Japan, we enrolled 123 eyes of 123 patients with Amsler-Krumeich classification stage 1 (<50 years of age [average 26.36 ± 8.68 years]; 84/39 male/female) and 205 eyes of 205 healthy subjects (average age 26.20 ± 7.34 years, 139/66 male/female). Participants were divided 2:1 into a prediction group and an application group. In the prediction group, multivariate logistic regression analysis was performed with keratoconus diagnosis as the dependent variable, and auto-keratometer parameters including average K, steep K, flat K, astigmatism, and astigmatic axis (no, with-the-rule, against-the-rule, and oblique) as independent variables. The diagnostic probability determined by regression analysis was defined as the keratometer keratoconus index. The cutoff value was determined from the receiver operating characteristic curve. This prediction equation was evaluated in the application group. Our primary outcome measure was the accuracy of the prediction equation for discriminating keratoconus from normal eyes. RESULTS: The selected explanatory variables were steep K (partial regression coefficient [β] 1.284, odds ratio [OR] 3.610), flat K (β -0.618, OR 0.539), and with-the-rule astigmatism (β -3.163, OR 0.042). The area under the receiver operating characteristic curve of keratometer keratoconus index was 0.90, which was significantly better than individual parameters (P < .001). The sensitivity and specificity values in the application group were 85.0% and 86.7%, respectively. CONCLUSIONS: Although the sensitivity/specificity was not high, the new prediction equation using auto-keratometer-derived parameters enabled better discrimination of early-stage keratoconus than the isolated parameters.
引用
- Kojima T, Nishida T, Nakamura T, et al. Keratoconus Screening Using Values Derived From Auto-Keratometer Measurements: A Multicenter Study. Am J Ophthalmol. 2020. PMID: 32114181. doi:10.1016/j.ajo.2020.02.017