无胶无缝线巩膜固定人工晶状体的改良简易法:回顾性病例系列
这项回顾性介入病例系列评估一种改良自封闭巩膜袋技术用于人工晶状体巩膜固定的结局与可行性,共纳入81眼,包括人工晶状体脱位及后囊膜缺失或晶状体半脱位病例。术后最佳矫正视力(BCVA)由术前LogMAR 1.2±0.59改善至LogMAR 0.47±0.3(P<0.001),平均术后散光1.27±1.02 Dcyl,AS-OCT与UBM均显示襻与光学部位置稳定、无倾斜。
要点
- 改良自封闭巩膜袋技术固定人工晶状体,术后BCVA较术前显著改善(P<0.001)。
- AS-OCT见巩膜内高反射影提示襻稳定,UBM示光学部无倾斜。
- 作者认为该术式缩短手术时间且并发症少。
核心结论
- 该改良简易巩膜固定人工晶状体技术可缩短手术时间且并发症少。
研究设计与样本
- 回顾性介入病例系列,共81眼,于既往4年内接受该改良技术。
- 病例包括人工晶状体脱位以及后囊膜缺失或晶状体半脱位。
- 在距角膜缘3 mm处制作两个对角相对的角巩膜缘旁弧形自封闭巩膜袋,并行玻璃体切除。
- 使用多片式人工晶状体,将襻固定于巩膜袋下、表层巩膜瓣下方的线性巩膜隧道内,结膜以烧灼对合。
- 术后行AS-OCT检测巩膜内襻的高反射横截面及光学部倾斜,并以UBM复核光学部位置。
主要发现
- 术前与术后平均BCVA分别为LogMAR 1.2±0.59与LogMAR 0.47±0.3(P<0.001)。
- 平均术后散光为1.27±1.02 Dcyl。
- AS-OCT中巩膜内高反射影提示襻稳定且无光学部倾斜。
- UBM亦显示人工晶状体光学部位置稳定、无倾斜。
临床怎么用
- 对人工晶状体脱位或后囊膜缺失、晶状体半脱位病例,可考虑该无胶无缝线巩膜袋固定术式。
- 术后可用AS-OCT与UBM评估襻位置及光学部倾斜。
局限性
- 原文未报告局限性相关内容。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the outcome and viability of a modified self-sealing scleral pocket technique for scleral fixation of an intraocular lens (IOL). DESIGN: Retrospective interventional case series. METHODS: A retrospective, interventional case series in which 81 eyes underwent this modified technique, performed in the previous 4 years. Cases included a dislocated IOL and an absent posterior capsule or subluxated cataract. Two diagonally opposed paralimbal, curved self-sealing scleral pockets were made 3 mm away from the limbus along with a vitrectomy. A multipiece IOL was used, and the haptics were fixed under the scleral pockets inside a linear scleral tunnel underneath the superficial scleral flap. The conjunctiva was opposed by using cautery. Postoperatively, anterior segment optical coherence tomography (AS-OCT) was performed in order to detect intrascleral hyper-reflective cross-section of the haptics and optic tilt. The optic position was re-evaluated using ultrasound biomicroscopy (UBM). Main outcomes were mean pre- and postoperative best corrected visual acuity (BCVA), postoperative astigmatism. Postoperative AS-OCT was performed to detect the position of the haptics and optics. UBM was done to recheck any optic tilt. RESULTS: Mean pre- and postoperative BCVA were LogMAR 1.2 ± 0.59 and LogMAR 0.47 ± 0.3 (P < 0.001). Mean postoperative astigmatism was 1.27 ± 1.02 Dcyl. In AS-OCT, an intrascleral hyper-reflective shadow signified stable haptics without any optic tilt. UBM also showed a stable position of the IOL optic without any tilt. CONCLUSIONS: This modified, simple way of scleral fixation of an IOL decreases the duration of surgery with minimal complication.
引用
- Boral SK, Agarwal D. A Simple Modified Way of Glueless, Sutureless Scleral Fixation of an IOL: A Retrospective Case Series. Am J Ophthalmol. 2020. PMID: 32222364. doi:10.1016/j.ajo.2020.03.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。