后囊膜混浊的根除:5416例尸检人工晶状眼分析显示Nd:YAG激光后囊切开率显著下降
该研究对1988年至2000年间获取的5416例尸检人工晶状体眼进行Miyake-Apple后部摄影分析,记录Nd:YAG激光后囊切开率。四种较老设计的人工晶状体后方囊切开率为20.3%至33.4%,而四种现代折叠式硅胶和丙烯酸人工晶状体为0.9%至17.1%,差异显著(P < 0.0001)。折叠式人工晶状体后方囊切开率(14.1%)远低于硬性设计(31.1%)。作者认为通过手术技术和人工晶状体选择的六项因素,后囊膜混浊及Nd:YAG激光后囊切开率正从20世纪80年代至90年代初的高达50%迅速下降,有望降至个位数。
要点
- 现代折叠式丙烯酸和硅胶人工晶状体后方囊切开率显著低于较老设计。
- 折叠式人工晶状体后方囊切开率14.1%,硬性设计为31.1%。
- 八种人工晶状体设计间后方囊切开率差异显著(P < 0.0001)。
核心结论
- 后囊膜混浊及Nd:YAG激光后囊切开率正迅速下降,通过手术技术和人工晶状体选择的六项因素有望实现虚拟根除。
研究设计与样本
- 比较性尸检组织分析,纳入1988年至2000年间来自Lions Eye Banks的5416例后房型人工晶状体眼,采用Miyake-Apple后部摄影技术。
主要发现
- 四种较老设计的人工晶状体后方囊切开率为20.3%至33.4%。
- 四种现代折叠式硅胶和丙烯酸人工晶状体后方囊切开率为0.9%(Alcon Acrysof)至17.1%。
- 八种人工晶状体设计间后方囊切开率差异显著(P < 0.0001,卡方检验)。
- 折叠式人工晶状体后方囊切开率为14.1%,硬性设计为31.1%。
临床怎么用
- 选择现代折叠式丙烯酸或硅胶人工晶状体并应用文中所述手术技术,可降低后囊膜混浊及Nd:YAG激光后囊切开率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: (1) To report the neodymium:yttrium-aluminum-garnet (Nd:YAG) laser posterior capsulotomy rate (%) of eight rigid and foldable intraocular lens (IOL) designs in a series of 5416 pseudophakic human eyes obtained postmortem, accessioned in our center between January 1988 and January 2000. (2) To identify factors that are instrumental in reducing the incidence of posterior capsule opacification, (PCO, secondary cataract) and hence the need for Nd:YAG laser posterior capsulotomy. DESIGN: Comparative autopsy tissue analysis. PARTICIPANTS: A total of 5416 globes with posterior chamber intraocular lens (PC-IOLs) obtained postmortem received from Lions Eye Banks between 1988 and 2000. METHODS: Miyake-Apple posterior photographic technique. Special reference was given to the presence or absence of Nd:YAG laser posterior capsulotomy orifice on the posterior capsule of each eye. MAIN OUTCOME MEASURES: The Nd:YAG laser posterior capsulotomy rate (%) as of January 2000 was documented. In addition, the Nd:YAG laser posterior capsulotomy rate for each lens was plotted on a monthly basis for the same period, creating a computerized trend or "timeline" for each IOL style. RESULTS: Relatively high Nd:YAG laser posterior capsulotomy rates ranging from 20.3% to 33.4% were noted with four relatively older designs (high incidence of implantation between 1988 and the early 1990s). Four modern foldable lOLs manufactured from silicone and acrylic materials had significantly lower Nd:YAG laser posterior capsulotomy rates ranging from 0.9% (Alcon Acrysof) to 17.1%. The difference in Nd:YAG rates among the eight IOL designs was found to be significant (P < 0.0001, chi-square test). Comparing foldable versus rigid designs, the foldable IOLs were associated with a much lower Nd:YAG laser posterior capsulotomy rate (14.1% vs. 31.1%). CONCLUSIONS: By use of the six factors regarding surgical technique and IOL choice described in this article, we strongly believe that the overall incidence of PCO and hence the incidence of Nd:YAG laser posterior capsulotomy is now rapidly decreasing from rates as high as 50% in the 1980s to early 1990s. Surgical tools and IOLs are now available to bring these rates down to single digits. Careful application and use of these tools by surgeons can genuinely lead in the direction of virtual eradication of secondary cataract, the second most common cause of visual loss worldwide.
引用
- Apple DJ, Peng Q, Visessook N, et al. Eradication of Posterior Capsule Opacification: Documentation of a Marked Decrease in Nd:YAG Laser Posterior Capsulotomy Rates Noted in an Analysis of 5416 Pseudophakic Human Eyes Obtained Postmortem. Ophthalmology. 2020. PMID: 32200823. doi:10.1016/j.ophtha.2020.01.026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。