文献速递角膜与眼表疾病白内障与屈光手术

角膜断层扫描深度学习筛查屈光手术候选者

Screening Candidates for Refractive Surgery With Corneal Tomographic-Based Deep Learning.
PubMed 文献 · JAMA Ophthalmol · 2020-01-01

该诊断性横断面研究在中国广州中山眼科中心纳入1385例患者、6465张角膜断层扫描图像,构建以Pentacam InceptionResNetV2筛查系统(PIRSS)为核心的AI分类系统。PIRSS在独立测试集总体检测准确率为95%(95%CI,88.8%-97.8%),与资深屈光手术眼科医生相当(92.8%;95%CI,91.2%-94.4%)(P = .72);在区分屈光手术禁忌角膜方面优于Pentacam HR系统分类器(95% vs 81%;P < .001)。

要点

  • PIRSS在独立测试集总体检测准确率95%,与资深屈光手术医生相当。
  • 在区分屈光手术禁忌角膜时,PIRSS优于Pentacam HR系统分类器(95% vs 81%)。
  • PIRSS可辅助屈光手术医生初步识别高危角膜,但需在其他人群中验证。

核心结论

  • PIRSS对图像分类以提供角膜信息并初步识别高危角膜似乎有用,可指导屈光手术医生筛查候选者,并可能用于亚洲患者的通用临床场景,但需在其他人群中确认。

研究设计与样本

  • 诊断性横断面研究,地点为广州中山眼科中心,检查日期为2016年7月18日至2019年3月29日,研究实施时间为2018年7月2日至2019年6月28日。
  • 纳入1385例患者,使用6465张角膜断层扫描图像生成人工智能(AI)模型,数据采集使用Pentacam HR系统。

主要发现

  • PIRSS模型在验证数据集上总体检测准确率为94.7%(95%CI,93.3%-95.8%)。
  • PIRSS模型在独立测试数据集上总体检测准确率为95%(95%CI,88.8%-97.8%),与资深屈光手术眼科医生(92.8%;95%CI,91.2%-94.4%)相当(P = .72)。
  • 在亚洲患者数据库中区分屈光手术禁忌角膜时,PIRSS模型表现优于Pentacam HR系统分类器(95% vs 81%;P < .001)。

关键数值与推荐

  • 屈光手术禁忌角膜的区分以Pentacam HR系统分类器为对照,PIRSS准确率95% vs 81%(P < .001)。

临床怎么用

  • PIRSS可用于屈光手术前角膜断层扫描图像的分类,为屈光手术医生提供角膜信息并初步识别高危角膜,但需注意其适用性尚待其他人群验证。

局限性

  • 原文指出PIRSS的使用需要在其他人群中确认。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

IMPORTANCE: Evaluating corneal morphologic characteristics with corneal tomographic scans before refractive surgery is necessary to exclude patients with at-risk corneas and keratoconus. In previous studies, researchers performed screening with machine learning methods based on specific corneal parameters. To date, a deep learning algorithm has not been used in combination with corneal tomographic scans. OBJECTIVE: To examine the use of a deep learning model in the screening of candidates for refractive surgery. DESIGN, SETTING, AND PARTICIPANTS: A diagnostic, cross-sectional study was conducted at the Zhongshan Ophthalmic Center, Guangzhou, China, with examination dates extending from July 18, 2016, to March 29, 2019. The investigation was performed from July 2, 2018, to June 28, 2019. Participants included 1385 patients; 6465 corneal tomographic images were used to generate the artificial intelligence (AI) model. The Pentacam HR system was used for data collection. INTERVENTIONS: The deidentified images were analyzed by ophthalmologists and the AI model. MAIN OUTCOMES AND MEASURES: The performance of the AI classification system. RESULTS: A classification system centered on the AI model Pentacam InceptionResNetV2 Screening System (PIRSS) was developed for screening potential candidates for refractive surgery. The model achieved an overall detection accuracy of 94.7% (95% CI, 93.3%-95.8%) on the validation data set. Moreover, on the independent test data set, the PIRSS model achieved an overall detection accuracy of 95% (95% CI, 88.8%-97.8%), which was comparable with that of senior ophthalmologists who are refractive surgeons (92.8%; 95% CI, 91.2%-94.4%) (P = .72). In distinguishing corneas with contraindications for refractive surgery, the PIRSS model performed better than the classifiers (95% vs 81%; P < .001) in the Pentacam HR system on an Asian patient database. CONCLUSIONS AND RELEVANCE: PIRSS appears to be useful in classifying images to provide corneal information and preliminarily identify at-risk corneas. PIRSS may provide guidance to refractive surgeons in screening candidates for refractive surgery as well as for generalized clinical application for Asian patients, but its use needs to be confirmed in other populations.

来源:JAMA Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Xie Y, Zhao L, Yang X, et al. Screening Candidates for Refractive Surgery With Corneal Tomographic-Based Deep Learning. JAMA Ophthalmol. 2020. PMID: 32215587. doi:10.1001/jamaophthalmol.2020.0507

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。