梯度提升分类器联合血管密度与组织厚度测量用于早中期青光眼分类
本研究纳入180只健康眼和193只早中期青光眼眼,比较梯度提升分类器(GBC)联合OCTA测量的血管密度(VD)与OCT测量的组织厚度,与标准OCTA VD和OCT厚度参数在分类健康眼与早中期青光眼时的诊断准确性。结果显示GBC的AUROC为0.90至0.93,优于标准参数的0.64至0.91;黄斑厚度与ONH VD测量组合贡献最大。
要点
- GBC联合OCTA与OCT的黄斑和视神经乳头测量可提高青光眼诊断准确性。
- 全参数GBC的AUROC为0.93,显著优于ONH GBC和血管密度GBC。
- 黄斑厚度与ONH血管密度测量是全参数GBC中贡献最大的组合。
核心结论
- 联合OCTA和OCT黄斑及视神经乳头测量的GBC可提高青光眼诊断准确性,优于大多数但非全部仪器提供的参数。
研究设计与样本
- 诊断工具比较研究,纳入180只健康眼和193只早中期青光眼眼,进行黄斑和视神经乳头OCTA与OCT成像。
- 评估四种GBC:黄斑GBC、ONH GBC、血管密度GBC和厚度GBC,以及第五种全参数GBC。
- 采用ROC曲线(AUROC)分析比较GBC与标准仪器参数的诊断准确性。
主要发现
- GBC的AUROC范围为0.90至0.93,标准OCTA和OCT参数的AUROC范围为0.64至0.91。
- 其他GBC之间性能相似。
- 全参数GBC中各参数的相对影响均值显示,黄斑厚度和ONH血管密度测量组合贡献最大。
临床怎么用
- 临床可考虑联合OCTA血管密度与OCT组织厚度测量构建GBC模型,以提高早中期青光眼诊断准确性。
- 黄斑厚度与ONH血管密度测量组合可能是诊断分类中的重要贡献参数。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare gradient-boosting classifier (GBC) analysis of optical coherence tomography angiography (OCTA)-measured vessel density (VD) and OCT-measured tissue thickness to standard OCTA VD and OCT thickness parameters for classifying healthy eyes and eyes with early to moderate glaucoma. DESIGN: Comparison of diagnostic tools. METHODS: A total of 180 healthy eyes and 193 glaucomatous eyes with OCTA and OCT imaging of the macula and optic nerve head (ONH) were studied. Four GBCs were evaluated that combined 1) all macula VD and thickness measurements (Macula GBC), 2) all ONH VD and thickness measurements (ONH GBC), 3) all VD measurements from the macula and ONH (vessel density GBC), and 4) all thickness measurements from the macula and ONH (thickness GBC). ROC curve (AUROC) analyses compared the diagnostic accuracy of GBCs to that of standard instrument-provided parameters. A fifth GBC that combined all parameters (full GBC) also was investigated. RESULTS: GBCs had better diagnostic accuracy than standard OCTA and OCT parameters with AUROCs ranging from 0.90 to 0.93 and 0.64 to 0.91, respectively. The full GBC (AUROC = 0.93) performed significantly better than the ONH GBC (AUROC = 0.91; P = .036) and the vessel density GBC (AUROC = 0.90; P = .010). All other GBCs performed similarly. The mean relative influence of each parameter included in the full GBC identified a combination of macular thickness and ONH VD measurements as the greatest contributors. CONCLUSIONS: GBCs that combine OCTA and OCT macula and ONH measurements can improve diagnostic accuracy for glaucoma detection compared to most but not all instrument provided parameters.
引用
- Bowd C, Belghith A, Proudfoot JA, et al. Gradient-Boosting Classifiers Combining Vessel Density and Tissue Thickness Measurements for Classifying Early to Moderate Glaucoma. Am J Ophthalmol. 2020. PMID: 32222368. doi:10.1016/j.ajo.2020.03.024