晚期青光眼患者单眼与双眼中心视野敏感度比较
本研究纳入51例至少一个中心10°内显著点的开角型青光眼患者,使用imo静态视野计比较单眼与双眼随机单眼测试的中心视觉敏感度。结果显示,较差眼在双眼条件下中心4点平均敏感度低于单眼条件,而较好眼则相反。
要点
- 较差眼在双眼条件下的中心4点平均敏感度低于单眼条件。
- 较好眼在双眼条件下的中心4点平均敏感度高于单眼条件。
- imo视野计的双眼测试可能有助于预测视野损害对视觉生活质量的影响。
核心结论
- 在青光眼患者中,较好眼的中心敏感度在双眼测试时优于单眼测试,而较差眼则更差。
研究设计与样本
- 横断面研究,纳入51例开角型青光眼患者的51只眼,均至少有一个中心10°内显著点。
- 使用imo视野计进行单眼和双眼随机单眼测试,并与Humphrey视野分析仪(HFA)24-2和10-2测试比较。
主要发现
- 较好眼HFA 24-2平均偏差为-5.5(-1.5,-14.6)dB(中位数,四分位距)。
- 较差眼HFA 24-2平均偏差为-18.0(-12.9,-23.8)dB。
- 较差眼中心4点平均敏感度在双眼条件下低于单眼条件。
- 较好眼中心4点平均敏感度在双眼条件下高于单眼条件。
临床怎么用
- 单眼视野测试仍是临床监测青光眼最直接的方法。
- imo视野计的双眼测试可作为预测视野损害对患者视觉生活质量影响的临床工具。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND/AIM: This study aimed to compare central visual sensitivity under monocular and binocular conditions in patients with glaucoma using the new imo static perimetry. METHODS: Fifty-one consecutive eyes of 51 patients with open-angle glaucoma who were affected with at least one significant point in the central 10° were examined in this cross-sectional study. Monocular and binocular random single-eye tests were performed using the imo perimeter and the Humphrey field analyser (HFA) 24-2 and 10-2 tests. The eyes were assigned to 'better' and 'worse' categories based on the visual acuity and central visual thresholding. Central visual sensitivity results obtained by monocular, binocular random single-eye tests and binocular simultaneous both eye test were compared. RESULTS: The average mean deviation with the HFA 24-2 was -5.5 (-1.5, -14.6) dB (median, (IQR)) in the better eyes and -18.0 (-12.9, -23.8) dB in the worse eyes. The mean sensitivity in the central 4 points of the visual field (VF) of the worse eyes was lower when measured under the binocular eye condition than under the monocular condition. Conversely, this value of the better eyes was greater when measured under the binocular eye condition than under the monocular condition. CONCLUSIONS: The central sensitivity of the better eyes was better and that of the worse eyes poorer with binocular testing than with monocular testing in patients with glaucoma. Although monocular VF testing is still the most straightforward means to monocularly monitor glaucoma at clinical settings, binocular testing, such as provided with imo perimetry, may be a useful clinical tool to predict the effect of VF impairments on a patient's quality of visual life.
引用
- Kumagai T, Shoji T, Yoshikawa Y, et al. Comparison of central visual sensitivity between monocular and binocular testing in advanced glaucoma patients using imo perimetry. Br J Ophthalmol. 2020. PMID: 32152139. doi:10.1136/bjophthalmol-2019-315251
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。