数据增强在青光眼视野趋势分析中的应用价值
本研究纳入417例开角型青光眼患者的638只眼共6380份视野,评估仿射变换数据增强对点wise线性回归预测第10次视野总偏差的效用,发现旋转、缩放、平移及组合变换可显著降低均方根误差,且组合变换使短视野序列的进展速率与VF1-10更一致。
要点
- 仿射变换数据增强可显著改善点wise线性回归预测视野总偏差的均方根误差。
- 组合仿射变换使短视野序列的进展速率与VF1-10一致性更好。
- 数据增强尤其适用于短视野序列的青光眼视野进展预测。
核心结论
- 在青光眼患者中使用点wise线性回归预测未来视野进展时,应用视野数据增强技术是有用的,尤其是短视野序列。
研究设计与样本
- 本研究纳入417例开角型青光眼患者的638只眼共6380份视野,采用仿射变换(旋转、缩放、垂直和水平平移及组合)增强视野数据,并以点wise线性回归预测第10次视野的总偏差值,计算均方根误差。
主要发现
- 无视野增强时,点wise线性回归的平均均方根误差从3.95 dB(VF1-3)至19.01 dB(VF1-9)。
- 应用旋转(VF1-3至VF1-7)、缩放(VF1-3至VF1-6)、垂直和水平平移(VF1-3至VF1-4)及组合变换(VF1-3至VF1-7)均显著改善均方根误差。
- 应用组合仿射变换时,VF1-10的进展速率与较短视野序列的一致性更好。
- 使用增强时,进展速率差异在1.9 dB(VF1-3)至0.39 dB(VF1-9)之间,显著小于未增强时的2.6 dB(VF1-3)至0.26 dB(VF1-9)。
临床怎么用
- 在临床或研究中利用点wise线性回归预测青光眼视野进展时,可考虑对视野数据应用仿射变换增强,以改善预测准确性,尤其当视野序列较短时。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To investigate the usefulness of data augmentation in visual field (VF) trend analyses in patients with glaucoma. METHOD: This study included 6380 VFs from 638 eyes of 417 patients with open-angle glaucoma. Various affine transformations were applied to augment the VF data: (1) rotation, (2) scaling, (3) vertical and horizontal shift and (4) a combination of these different transformations. Using pointwise linear regression (PLR), the total deviation (TD) values of a patient's 10th VF were predicted using TD values from shorter VF series (from first to third VFs (VF1-3) to first to ninth VFs (VF1-9)) with and without VF data augmentation, and the root mean squared error (RMSE) was calculated. RESULTS: With PLR, mean RMSE without VF augmentation averaged from 3.95 (VF1-3) to 19.01 (VF1-9) dB. The RMSE was significantly improved by applying the different transformations: (1) rotation (from VF1-3 to VF1-7), (2) scaling (from VF1-3 to VF1-6), (3) vertical and horizontal shifts (from VF1-3 to VF1-4) and (iv) a combination of these (from VF1-3 to VF1-7). Progression rates in VF1-10 had better agreement with those in shorter VF series when a combination of affine transformation was applied. The differences in rates were between 1.9 (VF1-3) and 0.39 (VF1-9) dB if augmentation was used, which was significantly smaller than that observed when augmentation was not applied (from 2.6 with VF1-3 to 0.26 dB with VF1-9). CONCLUSION: It is useful to apply VF data augmentation techniques when predicting future VF progression in glaucoma using PLR, especially with short VF series.
引用
- Asaoka R, Murata H, Matsuura M, et al. Usefulness of data augmentation for visual field trend analyses in patients with glaucoma. Br J Ophthalmol. 2020. PMID: 32111606. doi:10.1136/bjophthalmol-2019-315027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。