文献速递青光眼

小梁切除术中丝裂霉素C球周注射与海绵应用的效果比较

A Comparison of Trabeculectomy Surgery Outcomes With Mitomycin-C Applied by Intra-Tenon Injection Versus Sponge.
PubMed 文献 · Am J Ophthalmol · 2020-03-12

该回顾性研究纳入316只原发性或继发性青光眼患眼,比较小梁切除术中丝裂霉素C(MMC)球周注射与海绵应用的效果。注射法在降低眼压方面与海绵法相似,安全性相当。

要点

  • 年龄较大和角膜缘结膜切口与术后眼压控制失败时间更长相关。

核心结论

  • MMC球周注射与海绵应用在降低青光眼患者眼压方面效果相似,两种技术安全性相当。

研究设计与样本

  • 回顾性队列研究,纳入566例原发性或继发性青光眼患者,最终316只眼纳入分析,其中海绵组131眼、注射组185眼。

主要发现

  • 两组术后眼压控制失败时间无显著差异,但年龄较大和角膜缘结膜切口与失败时间更长显著相关。

关键数值与推荐

  • 主要结局为术后眼压水平,次要结局包括眼压控制生存率、青光眼药物使用、并发症率和视力。
  • 排除标准包括年龄小于18岁、无光感、联合手术、既往青光眼切开手术、术中5-氟尿嘧啶或随访不足1个月。

临床怎么用

  • MMC球周注射可作为海绵应用的替代方式,两者降眼压效果和安全性相当。
  • 选择角膜缘结膜切口可能延长术后眼压控制失败时间。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare the outcomes of mitomycin-C (MMC) delivered by intra-Tenon injection vs sponge application during trabeculectomy surgery. METHODS: We retrospectively reviewed 566 patients with primary and secondary glaucoma diagnoses who received trabeculectomy surgery with MMC in an academic medical center. Exclusion criteria were age less than 18 years, no light perception vision, combined surgery, previous glaucoma incisional surgery, intraoperative 5-fluorouracil, or follow-up <1 month. Subjects were divided into 2 cohorts: MMC delivered by sponge application or by intra-Tenon injection. Main outcome measures were postoperative intraocular pressure (IOP) level and secondary measures were survival rate for IOP control, glaucoma medication use, complication rate, and vision. RESULTS: After inclusion/exclusion criteria, 316 eyes were available for analysis; 131 eyes had MMC delivered via sponge and 185 eyes via injection. Mean postoperative IOP was not significantly different between treatment groups but change in IOP from baseline was lower in the sponge vs the injection group 24 months after surgery (P = .038). The MMC sponge group had significantly more tense, vascularized, or encapsulated blebs as a late complication (P = .046). Time to failure for postoperative IOP control was not significantly different between MMC treatment groups, but older patient age and limbus-based conjunctival incision were associated with significantly longer time to fail. CONCLUSIONS: The application of MMC by injection was similar to application by sponge in lowering IOP in patients with glaucoma and the safety of both techniques appears to be comparable. Limbus-based conjunctival incision had longer time to failure for postoperative IOP control vs fornix-based incision. NOTE: Publication of this article is sponsored by the American Ophthalmological Society.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Lim MC, Hom B, Watnik MR, et al. A Comparison of Trabeculectomy Surgery Outcomes With Mitomycin-C Applied by Intra-Tenon Injection Versus Sponge. Am J Ophthalmol. 2020. PMID: 32173343. doi:10.1016/j.ajo.2020.03.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。