高眼压治疗研究中中央角膜厚度与种族的关系
非裔美国人平均厚度较白人薄23 μm(555.7±40.0 μm vs 579.0±37.0 μm,P<0.0001)。结论提示OHTS受试者角膜较一般人群厚,中央角膜厚度可能影响压平眼压计在青光眼和高眼压诊疗中的准确性。
要点
- 非裔美国人平均中央角膜厚度较白人薄23 μm(P<0.0001)。
- 中央角膜厚度可能影响压平眼压计在青光眼和高眼压管理中的准确性。
核心结论
- OHTS受试者角膜较一般人群厚,非裔美国人角膜较白人薄。
- 中央角膜厚度可能影响压平眼压计在青光眼和高眼压诊断、筛查和管理中的准确性。
主要发现
- 非裔美国人平均中央角膜厚度为555.7±40.0 μm(n=318),比白人(579.0±37.0 μm)薄23 μm,P<0.0001。
- 与平均中央角膜厚度较大相关的其他因素包括较年轻年龄、女性性别和糖尿病。
关键数值与推荐
- 非裔美国人平均中央角膜厚度555.7±40.0 μm(n=318),白人579.0±37.0 μm,差异23 μm,P<0.0001。
临床怎么用
- 在青光眼和高眼压患者的诊断、筛查和管理中,应考虑中央角膜厚度对压平眼压测量准确性的影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Central corneal thickness influences intraocular pressure (IOP) measurement. We examined the central corneal thickness of subjects in the Ocular Hypertension Treatment Study (OHTS) and determined if central corneal thickness is related to race. DESIGN: Cross-sectional study. PARTICIPANTS: One thousand three hundred one OHTS subjects with central corneal thickness measurements. INTERVENTION: Central corneal thickness was determined with ultrasonic pachymeters of the same make and model at all clinical sites of the OHTS. MAIN OUTCOME MEASURES: Correlation of mean central corneal thickness with race, baseline IOP, refraction, age, gender, systemic hypertension, and diabetes. RESULTS: Mean central corneal thickness was 573.0 ± 39.0 μm. Twenty-four percent of the OHTS subjects had central corneal thickness > 600 μm. Mean central corneal thickness for African American subjects (555.7 ± 40.0 μm; n = 318) was 23 μm thinner than for white subjects (579.0 ± 37.0 μm; P < 0.0001). Other factors associated with greater mean central corneal thickness were younger age, female gender, and diabetes. CONCLUSIONS: OHTS subjects have thicker corneas than the general population. African American subjects have thinner corneas than white subjects in the study. The effect of central corneal thickness may influence the accuracy of applanation tonometry in the diagnosis, screening, and management of patients with glaucoma and ocular hypertension.
引用
- Brandt JD, Beiser JA, Kass MA, et al. Central Corneal Thickness in the Ocular Hypertension Treatment Study (OHTS). Ophthalmology. 2020. PMID: 32200829. doi:10.1016/j.ophtha.2020.01.028
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。