文献速递青光眼眼底病与葡萄膜炎

部分性玻璃体后脱离对OCT视网膜神经纤维层厚度测量的影响

Effect of partial posterior vitreous detachment on spectral-domain optical coherence tomography retinal nerve fibre layer thickness measurements.
PubMed 文献 · Br J Ophthalmol · 2020-02-12

在麻省眼耳医院青光眼门诊连续684例患者中,37%至少一眼存在部分性玻璃体后脱离(pPVD)。对101只可疑青光眼眼的分析显示,有pPVD眼平均RNFL厚度大于无pPVD眼(p=0.02),下方和上方象限差异显著,校正年龄相关下降后差异仍显著(p=0.05)。

要点

  • pPVD与OCT测量的RNFL厚度偏高相关,评估可疑青光眼时需谨慎解读。
  • 684例中253例(37%)至少一眼存在pPVD。
  • 101只可疑青光眼眼中,有pPVD眼平均RNFL更厚(p=0.02),下方和上方象限差异显著。

核心结论

  • 部分性玻璃体后脱离与谱域OCT测量的视网膜神经纤维层厚度偏厚相关,在可疑青光眼评估中应审慎解读该发现。

研究设计与样本

  • 回顾性比较研究,纳入麻省眼耳医院青光眼门诊连续684例患者的谱域OCT RNFL厚度测量。
  • 比较101只符合纳入标准的可疑青光眼眼(55只有pPVD,46只无pPVD)的RNFL厚度。

主要发现

  • 684例患者中253例(37%)至少一眼存在pPVD。
  • 101只可疑青光眼眼中,有pPVD眼平均RNFL厚度大于无pPVD眼(p=0.02)。
  • 下方象限(p=0.004)和上方象限(p=0.008)RNFL厚度显著更厚,鼻侧(p=0.10)和颞侧(p=0.25)无显著差异。
  • 校正年龄相关RNFL厚度下降后,平均RNFL厚度差异仍显著(p=0.05)。

临床怎么用

  • 在可疑青光眼患者中,若存在pPVD,OCT测量的RNFL厚度可能偏厚,需结合临床综合判断。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND/AIMS: To assess the effect of partial posterior vitreous detachment (pPVD) on spectral-domain optical coherence tomography (OCT) peripapillary retinal nerve fibre layer thickness (RNFL) measurements. METHODS: Spectral-domain OCT RNFL thickness measurements were obtained from 684 consecutive patients who were seen in the Massachusetts Eye and Ear Glaucoma Service. Of these patients, we compared RNFL thickness measurements between 101 eyes of 101 glaucoma suspects who met inclusion criteria (55 eyes with and 46 eyes without pPVD). RESULTS: Among all 684 patients, 253 (37%) had pPVD in at least one eye. Among a subset of 101 eyes of 101 glaucoma suspects, average RNFL thickness was greater in eyes with compared to eyes without pPVD (p=0.02). Measurements were significantly greater in the inferior (p=0.004) and superior quadrants (p=0.008), but not in the nasal (p=0.10) and temporal quadrants (p=0.25). The difference in average RNFL thickness remained significant (p=0.05) even when corrected for expected age-related decline in RNFL thickness. CONCLUSION: Over a third of patients were found on peripapillary spectral-domain OCT to have a pPVD, which was associated with greater RNFL thickness measurements. Judicious clinical interpretation of this finding on spectral-domain OCT RNFL thickness scans should be factored into the assessment of glaucoma suspects.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Liu Y, Baniasadi N, Ratanawongphaibul K, et al. Effect of partial posterior vitreous detachment on spectral-domain optical coherence tomography retinal nerve fibre layer thickness measurements. Br J Ophthalmol. 2020. PMID: 32051132. doi:10.1136/bjophthalmol-2019-314570

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。