青光眼与健康人黄斑OCT血管成像的不对称性分析
本研究分析95例青光眼患者和59例对照者的黄斑OCT-A图像,计算整体灌注密度(PD)和灌注不对称指数(PAI)。PAI与视野平均偏差的相关性(r=0.47)强于PD(r=0.35),但与神经节细胞层(GCL)厚度的相关性相当(r=0.45 vs 0.43)。PAI在青光眼组比对照组低17%,PD低12%,但两者诊断准确性均不及GCL厚度。
要点
- PAI与视野平均偏差的相关性优于PD,但与GCL厚度相关性相当。
- 青光眼组PAI较对照组低17%,PD低12%。
- PD和PAI的诊断准确性均不如GCL厚度。
核心结论
- PAI与视野平均偏差和GCL厚度的相关性更好,且对青光眼与健康对照的区分略有改善,但诊断准确性仍低于GCL厚度。
研究设计与样本
- 研究分析了95例青光眼患者和59例对照者的黄斑OCT-A扫描,导出浅层血管丛的二维投影图像,计算整体PD和图像不对称性,并构建包含PD和不对称性(1:1权重)的无符号灌注不对称指数(PAI)。
主要发现
- 青光眼组视野平均偏差中位数(IQR)为-1.73(-3.76, 0.30)dB,对照组为0.67(0.16, 1.18)dB。
- PAI与视野平均偏差的相关性(r=0.47)强于PD(r=0.35),而与GCL厚度的相关性两者相当(r=0.45和0.43)。
- 与对照组相比,青光眼组平均PD低12%(0.27 vs 0.30),PAI低17%(0.40 vs 0.48)。
- PD或PAI的诊断准确性均不如GCL厚度。
临床怎么用
- 在青光眼评估中,PAI可能比单独PD更好地反映视野损害和结构改变,但诊断准确性仍不及GCL厚度,需结合GCL厚度等结构指标综合判断。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND/AIMS: Quantitative analysis of optical coherence tomography angiography (OCT-A) images requires a reproducible approach that accounts for sectoral loss. The objective of this study was to determine whether an index that accounts for both global (perfusion density, PD) and asymmetric loss of perfusion, rather than PD alone, more reliably measures loss of perfusion in patients with glaucoma. METHODS: We analysed macular OCT-A scans of 95 glaucoma patients and 59 control subjects. Two-dimensional projection images corresponding to the superficial vascular plexus were exported and analyses performed to calculate global PD and image asymmetry. An unsigned perfusion asymmetry index (PAI) that included PD and asymmetry (with 1:1 wt) was calculated. Perfusion density and PAI were compared with 10-2 visual field mean deviation and ganglion cell layer (GCL) thickness. RESULTS: Median (IQR) visual field mean deviation was -1.73 (-3.76, 0.30) dB for the glaucoma group and 0.67 (0.16, 1.18) dB for the control group. The strength of the correlation with mean deviation was stronger for PAI (r=0.47), compared with PD (r=0.35), whereas with GCL thickness they were comparable (r=0.45 and 0.43, respectively). Compared with controls, mean PD was 12% lower in patients with glaucoma (0.27 vs 0.30), while PAI was 17% lower (0.40 vs 0.48). However, diagnostic accuracy of either PD or PAI was worse than GCL thickness. CONCLUSIONS: While PAI yielded better correlation with mean deviation and GCL thickness, and a slightly improved separation between patients with glaucoma and healthy controls, diagnostic accuracy was inferior compared with GCL thickness.
引用
- Smith CA, West ME, Sharpe GP, et al. Asymmetry analysis of macular optical coherence tomography angiography in patients with glaucoma and healthy subjects. Br J Ophthalmol. 2020. PMID: 32107207. doi:10.1136/bjophthalmol-2019-315592
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。