文献速递青光眼

图形视网膜电图在视野前期与视野期青光眼中的应用

Pattern Electroretinograms in Preperimetric and Perimetric Glaucoma.
PubMed 文献 · Am J Ophthalmol · 2020-02-20

结果显示PERG N95振幅从对照组到视野前期组再到视野期组依次降低,且在存在RNFL缺损的视野前期患者中,N95振幅的诊断性能优于MD。

要点

  • PERG N95振幅在对照组、视野前期青光眼组和视野期青光眼组间依次显著降低(P < .001)。
  • 视野前期青光眼患者中,存在RNFL缺损与较低的PERG N95振幅相关(P = .013)。
  • 在存在RNFL缺损的视野前期组中,N95振幅的AUC(0.779)大于MD(0.533,P = .005)。

核心结论

  • PERG N95振幅从对照组到视野前期青光眼组降低,在视野期青光眼组进一步降低。
  • PERG N95振幅可补充用于检测早期青光眼性损害的功能评估。
  • 除N95振幅外的PERG参数因在视野前期青光眼中诊断性能相对较低,临床实用性似乎有限。

研究设计与样本

  • 横断面观察性研究。
  • 使用谱域光学相干断层扫描和商用ERG刺激器分别进行结构和功能测量。

主要发现

  • 平均视网膜神经纤维层(RNFL)和神经节细胞-内丛状层(GCIPL)厚度在视野期组最薄,其次为视野前期组和对照组(P < .001)。
  • PERG N95振幅在对照组最大,其次为视野前期组和视野期组(P < .001)。
  • 视野前期青光眼患者中,存在RNFL缺损与较低的PERG N95振幅相关(P = .013)。
  • N95振幅与平均RNFL厚度(r = 0.336,P < .001)和GCIPL厚度(r = 0.376,P < .001)呈显著关系。
  • 在存在RNFL缺损的视野前期组中,N95振幅的受试者工作特征曲线下面积(0.779)大于MD(0.533,P = .005)。

关键数值与推荐

  • 视野期青光眼组纳入标准为平均偏差(MD)>-10 dB。
  • PERG N95振幅在对照组、视野前期组和视野期组间差异显著(P < .001)。
  • 存在RNFL缺损的视野前期组中,N95振幅AUC为0.779,MD AUC为0.533(P = .005)。

临床怎么用

  • PERG N95振幅可作为检测早期青光眼性损害的功能评估补充手段。
  • 在视野前期青光眼尤其存在RNFL缺损时,N95振幅可能比MD提供更好的诊断性能。
  • 除N95振幅外的PERG参数在视野前期青光眼临床应用中因诊断性能较低而受限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To investigate whether visual function can be graded in detail using pattern electroretinogram (PERG) in preperimetric to perimetric glaucoma. DESIGN: Cross-sectional observational study. METHODS: Twenty-six normal subjects, 113 preperimetric glaucoma patients (which included glaucoma suspect patients), and 52 early perimetric glaucoma patients with a mean deviation (MD) >-10 dB were included. Structural and functional measurements were performed using spectral-domain optical coherence tomography and a commercial ERG stimulator, respectively. RESULTS: The average retinal nerve fiber layer (RNFL) and ganglion cell-inner plexiform layer (GCIPL) thickness were thinnest in the perimetric group, followed by the preperimetric group and the control group (P < .001). PERG N95 amplitude was the largest in the control group, followed by the preperimetric group and the perimetric group (P < .001). Among the preperimetric glaucoma patients, presence of the RNFL defect was associated with lower PERG N95 amplitude (P = .013). The N95 amplitude showed a significant relationship with average RNFL thickness (r = 0.336, P < .001) and GCIPL thickness (r = 0.376, P < .001). In the preperimetric group with the RNFL defect, the N95 amplitude showed larger areas under the receiver operating characteristic curve (0.779) than the MD (0.533, P = .005). CONCLUSIONS: PERG N95 amplitudes decreased from the control to preperimetric glaucoma group and were reduced more in perimetric glaucoma. The functional assessment for detecting early glaucomatous damage could be complemented by PERG N95 amplitude. Usefulness of PERG parameters except N95 amplitude seemed to be limited in a clinical setting because of relatively low diagnostic performance in preperimetric glaucoma.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Jung KI, Jeon S, Shin DY, et al. Pattern Electroretinograms in Preperimetric and Perimetric Glaucoma. Am J Ophthalmol. 2020. PMID: 32087144. doi:10.1016/j.ajo.2020.02.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。