文献速递眼底病与葡萄膜炎

基于金纳米颗粒试纸条的家庭尿8-OHdG检测用于糖尿病视网膜病变筛查

Diabetic Retinopathy Screening Using a Gold Nanoparticle-Based Paper Strip Assay for the At-Home Detection of the Urinary Biomarker 8-Hydroxy-2'-Deoxyguanosine.
PubMed 文献 · Am J Ophthalmol · 2020-02-06

本研究评估了一种基于智能手机和金纳米颗粒比色侧流免疫分析试纸条的尿8-羟基-2'-脱氧鸟苷(8-OHdG)定量方法,用于糖尿病视网膜病变(DR)筛查。在97例接受DR筛查的糖尿病患者中,低风险组平均尿8-OHdG为22±10 ng/mg肌酐,高风险组为55±11 ng/mg肌酐。以8-OHdG>50 ng/mg肌酐或尿肌酐>1.5 mg为筛查 cutoff 值,灵敏度91%、特异度81%。

要点

  • 金纳米颗粒试纸条可定量检测尿8-OHdG,且准确、精密、稳定。
  • 高危DR患者尿8-OHdG水平高于低危患者。
  • cutoff值>50 ng/mg肌酐或尿肌酐>1.5 mg时灵敏度91%、特异度81%。

核心结论

  • 尿8-OHdG是筛查糖尿病视网膜病变的有用生物标志物。
  • 基于侧流免疫分析试纸条和智能手机相机的定量8-OHdG检测在DR筛查中具有潜力。

研究设计与样本

  • 研究纳入97例接受DR筛查的糖尿病患者,其中包括7视野眼底照相。
  • DR按标准方法分级为低风险(无或轻度DR)和高风险(中度或重度DR)。
  • 对患者尿液样本进行试纸条传感器检测,并将8-OHdG值与DR分级进行相关性分析。

主要发现

  • 低风险组平均尿8-OHdG浓度为22±10 ng/mg肌酐。
  • 高风险组平均尿8-OHdG浓度为55±11 ng/mg肌酐。
  • 试纸条可定量测量8-OHdG,且准确、精密、稳定。

关键数值与推荐

  • 筛查cutoff值为8-OHdG>50 ng/mg肌酐或尿肌酐>1.5 mg时,灵敏度91%、特异度81%。

临床怎么用

  • 该试纸条结合智能手机相机可用于糖尿病患者DR的初步筛查。
  • 尿8-OHdG定量检测可作为DR筛查的辅助工具。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: We sought to assess a smartphone-based, gold nanoparticle-based colorimetric lateral flow immunoassay paper sensor for quantifying urine 8-hydroxy-2'-deoxyguanosine (8-OHdG) as a biomarker for diabetic retinopathy (DR) screening. METHODS: Paper strips incorporate gold nanoparticle-8-OHdG antibody conjugates that produce color changes that are proportional to urine 8-OHdG and that are discernible on a smartphone camera photograph. Paper strip accuracy, precision, and stability studies were performed with 8-OHdG solutions of varying concentrations. Urine was collected from 97 patients with diabetes who were receiving DR screening examinations, including 7-field fundus photographs. DR was graded by standard methods as either low risk (no or mild DR) or high risk (moderate or severe DR). Paper sensor assays were performed on urine samples from patients and 8-OHdG values were correlated with DR grades. The differences in 8-OHdG values between the low- and high-risk groups were analyzed for outliers to identify the threshold 8-OHdG value that would minimize false-negative results. RESULTS: Lateral flow immunoassay paper strips quantitatively measure 8-OHdG and were found to be accurate, precise, and stable. Average urine 8-OHdG concentrations in study patients were 22 ± 10 ng/mg of creatinine in the low-risk group and 55 ± 11 ng/mg of creatinine in the high-risk group. Screening cutoff values of 8-OHdG >50 ng/mg of creatinine or urine creatinine >1.5 mg minimized screen failures, with 91% sensitivity and 81% specificity. CONCLUSIONS: Urinary 8-OHdG is a useful biomarker to screen DR. Quantitative 8-OHdG detection with the lateral flow immunoassay paper sensor and smartphone camera demonstrates its potential in DR screening. NOTE: Publication of this article is sponsored by the American Ophthalmological Society.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Hainsworth DP, Gangula A, Ghoshdastidar S, et al. Diabetic Retinopathy Screening Using a Gold Nanoparticle-Based Paper Strip Assay for the At-Home Detection of the Urinary Biomarker 8-Hydroxy-2'-Deoxyguanosine. Am J Ophthalmol. 2020. PMID: 32035831. doi:10.1016/j.ajo.2020.01.032

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。