文献速递青光眼

选择性激光小梁成形术在开角型青光眼或高眼压症中成功的预测因素:基线眼压测量是否有预测作用?

Predictors of selective laser trabeculoplasty success in open angle glaucoma or ocular hypertension: does baseline tonography have a predictive role?
PubMed 文献 · Br J Ophthalmol · 2020-01-27

本研究回顾性分析了72例接受首次360°选择性激光小梁成形术(SLT)的开角型青光眼(OAG)或高眼压症(OHT)患者,评估基线眼压测量参数对治疗成功的预测作用。多变量回归分析显示,仅基线眼压(IOP)与治疗成功相关(R2=0.32,beta=-0.51,p<0.001,95%CI -2.02至-0.74),而基线房水流畅系数(TOF)无预测作用。

要点

  • 基线眼压是首次SLT治疗成功的唯一独立预测因素。
  • 基线房水流畅系数(TOF)与SLT治疗成功无关。
  • 研究纳入72例OAG或OHT患者,随访至少1年。

核心结论

  • 在首次接受360°SLT治疗的OAG或OHT患者中,基线眼压(而非基线TOF)是治疗后12个月成功的唯一决定因素。

研究设计与样本

  • 回顾性分析英国伦敦St Thomas医院2006年8月至2010年2月期间接受首次360°SLT且有可靠基线TOF测量及至少1年随访的OAG或OHT患者,最终72例符合标准。

主要发现

  • 多变量回归分析中,与成功相关的唯一变量是基线眼压(R2=0.32,beta=-0.51,p<0.001,95%CI -2.02至-0.74)。
  • 基线TOF未显示与SLT治疗成功相关。

关键数值与推荐

  • 基线眼压每升高1 mmHg,成功可能性降低(beta=-0.51,95%CI -2.02至-0.74,p<0.001)。
  • 基线TOF无显著预测作用(原文未报告具体统计值)。

临床怎么用

  • 临床选择首次SLT治疗患者时,可参考基线眼压水平预测治疗成功可能性,基线TOF不推荐作为预测指标。

局限性

  • 回顾性研究设计,样本量较小(72例),仅纳入有可靠基线TOF测量的患者,可能存在选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The determinants of success of selective laser trabeculoplasty (SLT) in treatment-naïve patients with open angle glaucoma (OAG) and ocular hypertension (OHT) have not been understood fully. Therefore, we have conducted this study to explore the predictors of success. METHODS: This is a retrospective review of a pre-existing database of patients who had received primary SLT at St Thomas' Hospital, London, UK. Patients with OAG and OHT who had received primary 360° SLT treatment and had reliable baseline tonographic outflow facility (TOF) with minimum of 1 year of follow-up were included. Univariate and multivariate analyses were performed to find the determinants of success. RESULTS: One hundred and seventy-four patients between August 2006 and February 2010 had received primary 360° SLT treatment and had baseline TOF measurement. Of these, 72 subjects fulfilled the eligibility criteria. In multivariate regression analysis, the only variable associated with success was baseline intraocular pressure (IOP) (R2=0.32, beta=-0.51, p<0.001, 95% CI -2.02 to -0.74). CONCLUSION: To our knowledge, this is the only study investigating the pretreatment TOF (measured with electronic Shiøtz tonography) and IOP as determinants of success 12 month's post-360° SLT in treatment-naïve patients with OAG and OHT. This study demonstrated that pretreatment IOP (and not TOF) is the only determinant of success after primary SLT therapy.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。