晚期青光眼患者对比敏感度评估:两种检测方法的比较
结果显示尽管视力接近正常,几乎所有患者均存在中度至重度CS缺陷,CS测量为晚期青光眼患者中心视觉功能提供了额外信息。
要点
- 晚期青光眼患者即使视力接近正常,仍普遍存在中度至重度对比敏感度缺陷。
- PR图表与FrACT测得的CS估计值高度相关(rho=0.88,p=0.001)。
- FrACT测得的CS比PR图表高0.09 log单位,PR图表的重测重复性区间窄46%。
核心结论
- 尽管视力接近正常,几乎所有晚期青光眼患者均表现出中度至重度对比敏感度缺陷。
- 对比敏感度测量可为晚期青光眼患者提供中心视觉功能的额外信息。
研究设计与样本
- 患者在1周至1个月内完成重测,检测包括视力、视野以及PR图表和FrACT对比敏感度测试。
主要发现
- 中位(IQR)年龄为61.5(55.5至69.2)岁,中位(IQR)视野平均偏差为-27.7(-29.7至-22.7)dB。
- 中位(IQR)视力为0.08 logMAR(0.02至0.16),相当于20/25(20/20至20/30)。
- 中位(IQR)对比敏感度:PR图表为1.35(1.11至1.51)log单位,FrACT为1.39(1.24至1.64)log单位。
- 视力仅解释对比敏感度变异的小于40%(调整R²=0.36)。
- 两种测试的对比敏感度估计值高度相关(rho=0.88,p=0.001),FrACT比PR图表高0.09 log单位,PR图表的95%重复性区间(Bland-Altman)窄46%。
临床怎么用
- 对晚期青光眼患者,即使视力尚可,也应考虑进行对比敏感度评估以全面了解中心视觉功能。
- PR图表与FrACT均可用于对比敏感度检测,两者结果高度相关但存在差异,临床解读时需注意测试方法间的可比性。
局限性
- 原文未明确报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: To evaluate contrast sensitivity (CS) in patients with advanced glaucomatous visual field damage, and to compare two clinical CS tests. METHODS: This was a cross-sectional test-retest study. Twenty-eight patients with open-angle glaucoma, visual acuity (VA) better than 20/40 and visual field mean deviation (MD) worse than -15 dB were enrolled. Patients underwent VA, visual field and CS testing with the Pelli-Robson (PR) chart and the Freiburg Visual Acuity and Contrast Test (FrACT). Retest measurements were obtained within 1 week to 1 month. RESULTS: Median (IQR) age and MD were 61.5 (55.5 to 69.2) years and -27.7 (-29.7 to -22.7) dB, respectively. Median (IQR) VA was 0.08 logarithm minimum angle of resolution (0.02 to 0.16), corresponding to 20/25 (20/20 to 20/30). Median (IQR) CS was 1.35 (1.11 to 1.51) log units with the PR chart and 1.39 (1.24 to 1.64) log units with FrACT. VA explained less than 40% of the variance in CS (adjusted R2=0.36). CS estimates of both tests were closely related (rho=0.88, p=0.001), but CS was 0.09 log units higher with FrACT compared with the PR chart, and the 95% repeatability intervals (Bland-Altman) were 46% tighter with the PR chart. CONCLUSIONS: Despite near-normal VA, almost all patients showed moderate to profound deficits in CS. CS measurement provides additional information on central visual function in patients with advanced glaucoma.
引用
- Jammal AA, Ferreira BG, Zangalli CS, et al. Evaluation of contrast sensitivity in patients with advanced glaucoma: comparison of two tests. Br J Ophthalmol. 2020. PMID: 31974085. doi:10.1136/bjophthalmol-2019-315273
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。