使用OCT血管成像测量青光眼视盘周围视网膜局灶性灌注损失
前瞻性观察性研究纳入47例原发性开角型青光眼(POAG)患者和36名正常受试者,利用OCT血管成像(OCTA)生成毛细血管密度图并定义低灌注区(LPA)和局灶性灌注损失(FPL)。POAG组LPA为3.40±2.29 mm²、FPL为21.8%±17.0%,均显著高于正常组(P < 0.001);LPA和FPL诊断青光眼的AUC均为0.965,敏感度93.7%(特异度95%),且FPL与视野平均偏差(MD)相关性优于神经纤维层(NFL)厚度。
要点
- OCTA可定量测量视盘周围视网膜低灌注区(LPA)和局灶性灌注损失(FPL)。
- POAG患者LPA和FPL显著高于正常人群,诊断准确性高(AUC 0.965)。
- FPL与视野MD的相关性(rho=-0.843)优于NFL厚度与视野MD的相关性。
核心结论
- 低灌注图及LPA、FPL参数能评估青光眼局灶性损伤的位置和严重程度,与视野良好一致。
研究设计与样本
- 前瞻性观察性研究,纳入47例POAG患者和36名正常受试者,每只眼接受4.5-mm OCTA扫描。
主要发现
- POAG组LPA为3.40±2.29 mm²,正常组为0.11±0.18 mm²(P < 0.001)。
- POAG组FPL为21.8%±17.0%,正常组为0.3%±0.7%(P < 0.001)。
- LPA和FPL诊断青光眼的AUC均为0.965,敏感度93.7%(特异度95%)。
- LPA和FPL的组内相关系数分别为0.977和0.958。
- FPL与视野MD的Spearman rho=-0.843,显著优于NFL厚度与视野MD的相关性(rho=0.760,P=0.008)。
关键数值与推荐
- 低灌注图定义为局部毛细血管密度低于正常参考人群0.5百分位且连续面积超过98.5百分位的区域。
- LPA为累积面积,FPL为低灌注区内相对于正常均值的毛细血管密度损失百分比积分。
临床怎么用
- OCTA测量的LPA和FPL可作为青光眼局灶性损伤评估的客观指标,与视野结果相关性良好。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To measure low perfusion areas (LPAs) and focal perfusion loss (FPL) in the peripapillary retina using OCT angiography (OCTA) in glaucoma. DESIGN: Prospective, observational study. PARTICIPANTS: A total of 47 patients with primary open-angle glaucoma (POAG) and 36 normal participants were analyzed. METHODS: One eye of each subject was scanned using an AngioVue (Optovue, Fremont, CA) 4.5-mm OCTA scan centered on the disc. En face nerve fiber layer (NFL) plexus angiogram was generated. With the use of custom software, a capillary density map was obtained by computing the fraction of area occupied by flow pixels after low-pass filtering by local averaging 21×21 pixels. The low-perfusion map is defined by local capillary density below 0.5 percentile over a contiguous area above 98.5 percentile of the normal reference population. The LPA parameter is the cumulative area, and the FPL is the percent capillary density loss (relative to normal mean) integrated over the LPA. MAIN OUTCOME MEASURES: Peripapillary retinal LPA and FPL. RESULTS: Among patients with POAG, 3 had preperimetric glaucoma and 44 had perimetric glaucoma, with visual field (VF) mean deviation (MD) of -5.14±4.25 decibels (dB). The LPA was 3.40±2.29 mm2 in those with POAG and 0.11±0.18 mm2 in normal subjects (P < 0.001). The FPL was 21.8%±17.0% in those with POAG and 0.3%±0.7% in normal subjects (P < 0.001). The diagnostic accuracy as measured by the area under the receiver operating curve was 0.965 for both LPA and FPL, with a sensitivity of 93.7% at 95% specificity. The repeatability as measured by intraclass correlation coefficient was 0.977 for LPA and 0.958 for FPL. The FPL had excellent correlation with VF MD (Spearman's rho = -0.843), which was significantly (P = 0.008) better than the correlation between NFL thickness and VF MD (rho = 0.760). The hemispheric difference correlation between FPL and VF (Spearman's rho = 0.770) was significantly (P < 0.001) higher than the hemispheric difference correlation between LPA and VF (rho = 0.595). CONCLUSIONS: The low-perfusion map and LPA and FPL parameters are able to assess the location and severity of focal glaucoma damage with good agreement with VF.
引用
- Chen A, Liu L, Wang J, et al. Measuring Glaucomatous Focal Perfusion Loss in the Peripapillary Retina Using OCT Angiography. Ophthalmology. 2019. PMID: 31899032. doi:10.1016/j.ophtha.2019.10.041
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。