视网膜脱离修复术后自适应光学下视力和感光细胞密度变化
PURPOSE: To quantify changes in photoreceptor density using adaptive optics fundus camera in patients after retinal detachment (RD) and to correlate them with macular involvement and best-corrected visual acuity.…
要点
- 黄斑未累及组术后视锥细胞密度增加(P=0.02),黄斑累及组未恢复(P=0.97)。
- 术后3个月内视锥细胞密度与视力及脱离类型独立相关(P=0.004,P=0.000)。
- 对侧眼视锥细胞密度在术后1至3个月保持稳定(P=0.67)。
核心结论
- 视网膜脱离修复术后黄斑累及组视锥细胞密度降低,黄斑未累及组虽也降低但在3个月随访期内恢复。
- 视锥细胞密度与视力及视网膜脱离类型在术后1个月和3个月均显著相关。
研究设计与样本
- 前瞻性研究,194例视网膜脱离修复术后患者在术后1个月和3个月接受自适应光学眼底成像,双眼5个位置采集图像并用解剖标志匹配。
主要发现
- 最佳矫正视力(logMAR及Snellen等效)在基线、术后1个月和3个月黄斑未累及组均优于黄斑累及组。
- 对侧眼视锥细胞密度在术后1至3个月保持稳定(P=0.67)。
- 治疗眼视锥细胞密度低于对侧眼(P<0.05)。
- 黄斑未累及组术后视锥细胞密度增加(P=0.02),黄斑累及组未增加(P=0.97)。
- 视力和视网膜脱离类型与视锥细胞密度独立相关(P=0.004,P=0.000)。
关键数值与推荐
- 基线最佳矫正视力:黄斑累及组2.0(2.3-0.95)(Snellen等效20/2000),黄斑未累及组0(0.1-0)(20/20)。
- 术后1个月最佳矫正视力:黄斑累及组0.35(0.5-0.1)(20/40),黄斑未累及组0.05(0-0.1)(20/25)。
- 术后3个月最佳矫正视力:黄斑累及组0.25(0.3-0.1)(20/32),黄斑未累及组0(0-0)(20/20)。
临床怎么用
- 自适应光学成像可用于量化视网膜脱离术后视锥细胞密度变化,辅助评估黄斑功能恢复。
- 黄斑累及患者术后视锥细胞密度恢复有限,需关注长期视功能预后。
局限性
- 随访时间仅3个月,长期变化未知。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To quantify changes in photoreceptor density using adaptive optics fundus camera in patients after retinal detachment (RD) and to correlate them with macular involvement and best-corrected visual acuity. METHODS: At 1 and 3 months (M1 and M3) after vitrectomy, 194 patients underwent adaptive optics imagery in both eyes, at 5 locations, that we matched between time points using anatomical landmarks. Twenty-two patients (10 fovea-OFF [OFF] and 12 fovea-ON [ON]) had matched and analyzable adaptive optics images. We used analysis of variance for repeated measures. RESULTS: Best-corrected visual acuity (logarithm of the minimum angle of resolution and Snellen equivalent [SE]) was significantly different between OFF and ON RDs at baseline: 2.0 (2.3-0.95) (SE: 20/2000) versus 0 (0.1-0) (SE: 20/20); at M1: 0.35 (0.5-0.1) (SE: 20/40) versus 0.05 (0-0.1) (SE: 20/25); and at M3: 0.25 (0.3-0.1) (SE: 20/32) versus 0 (0-0) (SE: 20/20). We observed that cone density was stable in fellow eyes between M1 and M3 (P = 0.67); decreased in treated eyes than in fellow eyes (P < 0.05); and increased postoperatively in the ON group (P = 0.02) but not in the OFF group (P = 0.97). Visual acuity and RD type were independently correlated with cone density (P = 0.004, P = 0.000). CONCLUSION: Postoperative cone density was reduced in OFF RD, but also in the ON group, although the drop recovered during the 3-month follow-up. Cone density was significantly correlated with both visual acuity and type of RD at both time points.