近红外反射成像用于量化年龄相关性黄斑变性萎缩
本研究回顾性纳入97例干性AMD伴地图状萎缩(GA)患眼,比较近红外反射(NIR)与眼底自发荧光(FAF)手动分割测量GA面积的可靠性。结果显示两种模态GA面积差异无统计学意义,重叠比0.84±0.28,Dice相似系数0.87±0.27,组内相关系数0.998(P<.01),NIR灵敏度94.8%。结论认为NIR可可靠识别和量化多数GA病变,但薄脉络膜导致等反射GA病变时可能具有挑战性。
要点
- NIR与FAF测量GA面积差异无统计学意义(P=.65),组内相关系数达0.998。
- NIR对GA检测灵敏度94.8%,5例(5.2%)FAF可见而NIR不可见。
- 薄脉络膜所致等反射GA病变可能限制NIR识别,临床需注意。
核心结论
- NIR图像可在多数病例中可靠识别和量化干性AMD的GA病变,但薄脉络膜导致等反射GA病变时可能具有挑战性。
研究设计与样本
- 回顾性组间可靠性分析,纳入97例干性AMD伴GA患者的97张共聚焦NIR图像和FAF图像,由两名设盲阅片中心分级者独立手动分割GA病变。
主要发现
- FAF图像平均GA面积为7.62±7.77 mm²,NIR为7.65±7.83 mm²,平均非显著差异0.31±0.55 mm²(双尾t检验,P=.65)。
- 两种模态分割GA病变的重叠比为0.84±0.28,Dice相似系数为0.87±0.27,组内相关系数=0.998(P<.01)。
- 5例(5.2%)GA病变在FAF图像上可识别而在NIR图像上不可识别,NIR灵敏度为94.8%。
关键数值与推荐
- GA在NIR/FAF图像上按近期发表的萎缩分类会议标准定义为边界清晰的高反射区域,直径≥250 μm。
临床怎么用
- NIR成像患者舒适且常与OCT同时获取,NIR-based GA评估可能作为临床环境中的有用替代方法。
局限性
- 回顾性研究设计,样本来自现有匿名化阅片中心数据集,薄脉络膜等反射GA病变可能影响NIR识别。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare measurements of area of geographic atrophy (GA) in dry age-related macular degeneration (AMD) obtained by fundus autofluorescence (FAF) to those obtained by near-infrared reflectance (NIR). DESIGN: Interrater reliability analysis. METHODS: Ninety-seven confocal NIR images (Heidelberg HRA + Spectralis) and FAF images from 97 patients/eyes with GA with dry AMD were collected retrospectively from existing anonymized Doheny Image Reading Center datasets. Two masked reading center graders (N.S., J.S.) independently and blindly performed manual segmentation of the GA lesions on each NIR and FAF image using GNU Image Manipulation Program software (version 2.8.22). GA on NIR/FAF images was defined in accordance to recently published Classification of Atrophy Meeting criteria as sharply demarcated hyperreflective regions ≥250 μm in diameter. The difference and point-to-point correspondence between gradings in GA area measurements between NIR and FAF were assessed by mean difference, overlap ratio, and Dice similarity coefficient. RESULTS: Among the 97 eyes with dry AMD, the mean GA area was 7.62 ± 7.77 mm2 from FAF images and 7.65 ± 7.83 mm2 from NIR, with a mean nonsignificant difference of 0.31 ± 0.55 mm2 (2-tailed t test, P = .65). The overlap ratio in the segmented GA lesion between modalities was 0.84 ± 0.28 with a Dice similarity coefficient of 0.87 ± 0.27. Intermodal reliability was high (intraclass correlation coefficient = 0.998, P < .01). Of note, in 5 cases (5.2%), the GA lesion could be identified on the FAF image but not on the NIR image, translating into a sensitivity of 94.8%. CONCLUSIONS: GA lesions in dry AMD can be identified and quantified reliably using NIR images in many cases, though eyes with a thin choroid resulting in isoreflective GA lesions may be challenging. NIR imaging is comfortable for patients and is commonly obtained along with OCT, and therefore NIR-based GA assessment may be a useful surrogate in clinical settings.
引用
- Abdelfattah NS, Sadda J, Wang Z, et al. Near-Infrared Reflectance Imaging for Quantification of Atrophy Associated with Age-Related Macular Degeneration. Am J Ophthalmol. 2020. PMID: 31945331. doi:10.1016/j.ajo.2020.01.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。