快速评估可避免盲(RAAB)的诊断准确性:一项基于人群的评估
本研究基于人群评估RAAB筛查盲与视力损害的诊断准确性,共纳入2145名50岁及以上受试者,其中1816人完成移动眼科诊所的复核检查。结果显示RAAB检测盲、经济盲、视力损害及白内障所致视力损害的敏感性、特异性与AUC均较高,但检测屈光不正所致视力损害的敏感性较低。
要点
- RAAB检测盲(PVA<3/60)的敏感性90.3%、特异性99.3%、AUC 0.948。
- RAAB检测白内障所致视力损害的敏感性90.5%、特异性98.1%、AUC 0.943。
- RAAB检测屈光不正所致视力损害的敏感性仅60.4%,特异性98.7%。
核心结论
- RAAB对盲、视力损害及白内障所致视力损害的患病率检测具有较高的诊断性能。
研究设计与样本
- 基于人群的诊断准确性研究,纳入2145名50岁及以上RAAB调查参与者,其中1816人同日接受移动眼科诊所的仪器复核检查。
主要发现
- RAAB检测盲(PVA<3/60)的敏感性90.3%、特异性99.3%、AUC 0.948、PLR 124.0、NLR 0.10。
- RAAB检测经济盲(PVA<6/60)的敏感性89.5%、特异性98.7%、AUC 0.940、PLR 69.2、NLR 0.11。
- RAAB检测视力损害(PVA<6/18)的敏感性90.3%、特异性97.7%、AUC 0.940、PLR 38.7、NLR 0.10。
- RAAB检测白内障所致视力损害的敏感性90.5%、特异性98.1%、AUC 0.943、PLR 48.1、NLR 0.10。
- RAAB检测屈光不正所致视力损害的敏感性60.4%、特异性98.7%、AUC 0.796、PLR 46.4、NLR 0.40。
关键数值与推荐
- 盲定义为较好眼视力<3/60,经济盲定义为<6/60,视力损害定义为<6/18。
- 主要致盲和视力损害原因依据较好眼的视力损害原因判定。
临床怎么用
- RAAB可用于人群水平盲与视力损害及白内障所致视力损害的快速评估。
- 对屈光不正所致视力损害的检测敏感性较低,需结合其他方法确认。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To evaluate the diagnostic accuracy of rapid assessment of avoidable blindness (RAAB). DESIGN: Population-based diagnostic accuracy study. METHODS: A total of 2145 (95.3%, 2145/2250) subjects aged 50 years and older who participated in the RAAB survey were included. All the recruited participants underwent ophthalmic examination according to the RAAB protocol and then were reexamined with instruments in a mobile eye clinic set up in a village center on the same day. Examination in the mobile clinic included standardized visual acuity (VA) tests using logMAR charts, refraction, slit-lamp biomicroscopy, and dilated fundal examination with a binocular indirect ophthalmoscope. Blindness and economic blindness were defined as VA in the better-seeing eye <3/60 and <6/60, respectively. Visual impairment (VI) was defined as VA <6/18 in the better eye. The primary cause of blindness and VI was defined according to the cause of VI in the participant's better eye. MAIN OUTCOME MEASURES: The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and area under the curve (AUC) of receiver operating characteristics of RAAB for detection of blindness and the principal causes of VI. RESULTS: A total of 1816 subjects (84.7%), including 686 men (37.8%) and 1130 women (62.2%), underwent ophthalmic examination in the mobile eye clinic. The mean (±standard deviation) age was 64.4 ± 9.6 years. The sensitivities, specificities, AUC, PLR, and NLR of RAAB were 90.3%, 99.3%, 0.948, 124.0, and 0.10, respectively, for detection of blindness (presenting visual acuity, PVA <3/60); 89.5%, 98.7%, 0.940, 69.2, and 0.11, respectively, for detection of economic blindness (PVA <6/60); and 90.3%, 97.7%, 0.940, 38.7, and 0.10, respectively, for detection of VI (PVA <6/18). The sensitivities, specificities, AUC, PLR, and NLR were 90.5%, 98.1%, 0.943, 48.1, and 0.10; and 60.4%, 98.7%, 0.796, 46.4, and 0.40 for detection of VI (PVA <6/18) owing to cataract and refractive error, respectively. CONCLUSION: The diagnostic performances of RAAB were high for detecting the prevalence of blindness, VI, and VI owing to cataract.
引用
- Zhang XJ, Leung CKS, Li EY, et al. Diagnostic Accuracy of Rapid Assessment of Avoidable Blindness: A Population-based Assessment. Am J Ophthalmol. 2019. PMID: 31846622. doi:10.1016/j.ajo.2019.12.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。