文献速递青光眼眼底病与葡萄膜炎

OCT对基于技术的眼保健服务方案诊断准确性的影响:TECS Compare试验第二部分

The Impact of OCT on Diagnostic Accuracy of the Technology-Based Eye Care Services Protocol: Part II of the Technology-Based Eye Care Services Compare Trial.
PubMed 文献 · Ophthalmology · 2019-10-31

该前瞻性研究纳入256例无已知眼病的常规检查患者,比较TECS方案联合OCT与面对面检查的一致性。结果显示OCT并未提高TECS方案诊断准确性,多数情况下无影响,且在一名阅片者中κ值从中等一致降至与机遇一致,符合率降低10%。作者结论为OCT未改善青光眼或视网膜疾病的检测准确性,需进一步研究确认。

要点

  • 在TECS方案中加入OCT未提高诊断准确性。
  • 多数情况下OCT无影响,一名阅片者κ值降至与机遇一致且符合率降低10%。
  • OCT未影响阅片者间或阅片者内变异性参数。

核心结论

  • 在TECS方案中加入OCT未改善青光眼或视网膜疾病的检测准确性。
  • 在一名阅片者中,OCT使与面对面检查的一致性从中等降至与机遇一致,符合率降低10%。

研究设计与样本

  • 前瞻性比较TECS方案联合OCT与面对面检查,共256例患者。
  • 纳入无已知眼病且希望常规眼科检查的患者。
  • 患者同日接受TECS方案检查、OCT视神经、OCT黄斑和面对面检查。

主要发现

  • OCT未提高TECS方案与面对面检查相比的诊断准确性。
  • 多数情况下OCT无影响。
  • 阅片者2的κ值从中等一致降至与机遇一致,符合率降低10%。
  • OCT未影响阅片者间或阅片者内变异性参数。

临床怎么用

  • 在非专家阅片者执行TECS方案时,不应常规依赖OCT来提高青光眼或视网膜疾病检测准确性。
  • 若阅片者为青光眼或视网膜专科医生而非非专家OCT阅片者、综合及前节专科医生,结果可能不同。

局限性

  • 需进一步研究确认这些发现。
  • 结果可能因阅片者专业背景不同而改变。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Ophthalmologic telemedicine programs help to address the growing demand for eye care and lessen healthcare disparities for patients. One example is Technology-Based Eye Care Services (TECS), implemented in the Veteran Affairs Healthcare System in 2015. Accuracy and quality data for TECS both have been reported, and data suggest that although the TECS examination is comparable with an in-person examination, sensitivity for glaucoma and glaucoma suspect detection is less than that for other diseases, such as macular degeneration. Several articles suggest that OCT can improve disease detection for glaucoma. Therefore, this study was undertaken to test the impact of OCT on the accuracy of the TECS protocol. This article reports the data from part II of the TECS Compare trial; results from part I are discussed in a previous article. DESIGN: Prospective comparison between the TECS protocol with OCT versus a face-to-face (FTF) examination for 256 patients. PARTICIPANTS: An eligible patient was defined as a patient with no known ocular disease who desired a routine eye examination. METHODS: Patient underwent the TECS protocol workup and OCT nerve, OCT macula, and FTF examination on the same day. MAIN OUTCOME MEASURES: Percent agreement, κ values, sensitivity, and specificity were calculated for nonexpert readers after OCT interpretation of the TECS protocol using the FTF examination as the clinical gold standard. RESULTS: OCT did not improve the diagnostic accuracy of the TECS protocol when compared with an FTF examination. In most cases, OCT had no impact, and in the case of reader 2, OCT actually reduced the κ value from moderate agreement to agreement equal to chance while lowering the percent agreement by 10%. OCT also did not impact inter- or intrareader variability parameters. CONCLUSIONS: In this study, OCT did not seem to improve the accuracy of glaucoma or retinal disease detection when added to the standard TECS protocol. In one case, OCT worsened the agreement of the reader compared with the FTF. Further study is necessary to confirm these findings, and results may change if the readers are glaucoma or retina specialists instead of nonexpert OCT readers, comprehensive and anterior segment specialists.

来源:Ophthalmology,查看原文。版权归原作者所有。

引用

  1. Maa AY, McCord S, Lu X, et al. The Impact of OCT on Diagnostic Accuracy of the Technology-Based Eye Care Services Protocol: Part II of the Technology-Based Eye Care Services Compare Trial. Ophthalmology. 2019. PMID: 31791664. doi:10.1016/j.ophtha.2019.10.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。