孔源性视网膜脱离初次玻璃体切除术中使用360度激光视网膜固定术的相关因素及对手术结局的影响
研究发现年轻年龄、更多视网膜裂孔、更广泛脱离及术者身份与使用360LR显著相关;360LR与单次手术解剖成功无显著关联,但在控制病例复杂度后与更低的最终解剖成功率和更差的最终视力显著相关。
要点
- 年轻年龄、更多裂孔、更广泛脱离及术者身份与360LR使用显著相关。
- 360LR与单次手术解剖成功、黄斑前膜、黄斑囊样水肿及后续玻璃体切除次数无显著关联。
- 控制病例复杂度后,360LR与更低的最终解剖成功率和更差的最终视力显著相关。
核心结论
- 多种因素影响孔源性视网膜脱离初次玻璃体切除术±巩膜扣带术中是否使用360LR。
- 360LR与手术结局改善无关,甚至可能与更差结局相关。
研究设计与样本
- 多中心、回顾性、干预性研究,评估2015年因非复杂原发性孔源性视网膜脱离行初次玻璃体切除术或初次玻璃体切除术+巩膜扣带术的患者。
- 采用多变量回归分析。
主要发现
- 年轻年龄(P=0.01)、更多视网膜裂孔(P=0.01)、更广泛RRD(P<0.001)及术者ID(P<0.001)与360LR显著相关。
- 360LR与单次手术解剖成功(P=0.44)、黄斑前膜形成(P=0.14)、黄斑囊样水肿发生(P=0.28)或后续玻璃体切除次数(P=0.41)无显著关联。
- 控制病例复杂度后,360LR与更低的最终解剖成功率(P<0.001)和更差的最终logMAR视力(P<0.001)显著相关。
关键数值与推荐
- 主要结局为单次手术解剖成功和最终解剖成功。
- 次要结局包括最终logMAR视力、黄斑前膜形成、黄斑囊样水肿发生及后续玻璃体切除次数。
临床怎么用
- 临床决策中应认识到360LR的使用受多种因素影响,且未显示改善手术结局,甚至可能与更差结局相关。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To determine factors associated with 360-degree laser retinopexy (360LR) during primary pars plana vitrectomy ± scleral buckle for rhegmatogenous retinal detachment (RRD) and its impact on surgical outcomes. METHODS: This is a multicenter, retrospective, interventional study. Patients undergoing primary pars plana vitrectomy or primary pars plana vitrectomy + scleral buckle for noncomplex primary RRD in 2015 were evaluated. Primary outcomes were single surgery anatomical success (SSAS) and final anatomical success. Secondary outcomes included final logarithm of the minimum angle of resolution visual acuity, epiretinal membrane formation, cystoid macular edema development, and number of subsequent vitrectomies. Multivariate regressions were performed. RESULTS: Two thousand two hundred and forty-eight surgeries by 61 surgeons were included; of which, 516 underwent 360LR. Younger age (P = 0.01), more retinal breaks (P = 0.01), more extensive RRD (P < 0.001), and surgeon ID (P < 0.001) were significantly associated with 360LR. No significant associations between 360LR and single surgery anatomical success (P = 0.44), epiretinal membrane formation (P = 0.14), cystoid macular edema development (P = 0.28), or number of subsequent vitrectomies (P = 0.41) were found. Controlling for case complexity, 360LR was significantly associated with lower final anatomical success (P < 0.001) and worse final logarithm of the minimum angle of resolution visual acuity (P < 0.001). CONCLUSION: Multiple factors influenced whether 360LR was performed during primary pars plana vitrectomy ± scleral buckle for RRD. However, 360LR was not associated with improved surgical outcomes, and in fact, it may be associated with poorer outcomes.
引用
- Wang JC, Ryan EH, Ryan C, et al. FACTORS ASSOCIATED WITH THE USE OF 360-DEGREE LASER RETINOPEXY DURING PRIMARY VITRECTOMY WITH OR WITHOUT SCLERAL BUCKLE FOR RHEGMATOGENOUS RETINAL DETACHMENT AND IMPACT ON SURGICAL OUTCOMES (PRO STUDY REPORT NUMBER 4). Retina. 2020. PMID: 31876884. doi:10.1097/IAE.0000000000002728
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。