文献速递眼底病与葡萄膜炎

荧光寿命成像检眼镜:黄斑脱离型孔源性视网膜脱离手术复位后的表现

FLUORESCENCE LIFETIME IMAGING OPHTHALMOSCOPY: Findings After Surgical Reattachment of Macula-Off Rhegmatogenous Retinal Detachment.
PubMed 文献 · Retina · 2020-01-01

结果显示,原脱离视网膜区域Tm显著延长,尤其SSC中央亚区;ETDRS网格中心短寿命与更好视力相关(SSC r=0.18,P=0.001;LSC r=0.08,P=0.03);4眼残留视网膜下液区域显示短荧光寿命。结论提示荧光寿命延长主要由黄斑色素丢失驱动,该技术可能有助于预测黄斑脱离型RRD术后长期功能预后。

要点

  • 黄斑脱离型RRD成功复位后,原脱离区视网膜荧光寿命显著延长,SSC中央亚区尤为明显。
  • ETDRS网格中心荧光寿命越短,视力越好(SSC r=0.18,P=0.001;LSC r=0.08,P=0.03)。
  • 残留视网膜下液区域显示短荧光寿命,黄斑色素丢失可能是寿命延长主因。

核心结论

  • 黄斑脱离型RRD成功复位后,原脱离视网膜区域荧光寿命显著改变,中心凹荧光寿命与视力显著相关,提示该技术可能用于预测长期功能预后。

研究设计与样本

  • 采用470 nm激发视网膜自发荧光,在短光谱通道(498-560 nm)和长光谱通道(560-720 nm)测量振幅加权平均荧光寿命(Tm),并在标准化ETDRS网格内分析。

主要发现

  • 原脱离视网膜区域在长光谱通道Tm显著延长,短光谱通道中央亚区尤为明显。
  • ETDRS网格中心短荧光寿命与更好视力相关:SSC r=0.18,P=0.001;LSC r=0.08,P=0.03。
  • 4例RRD眼残留视网膜下液区域显示短荧光寿命。

临床怎么用

  • 对黄斑脱离型RRD术后患者,可考虑用荧光寿命成像检眼镜评估黄斑区荧光寿命,辅助预测长期视力预后。
  • 解读时需注意中心凹荧光寿命延长可能主要反映黄斑色素丢失,而非仅结构改变。

局限性

  • 原文未报告敏感性、特异性或预测阈值,尚不能直接用于临床决策。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of this study was to investigate fluorescence lifetime imaging ophthalmoscopy lifetimes after macula-off rhegmatogenous retinal detachment (RRD) repair. METHODS: Fifty-eight patients with successful macula-off RRD reattachment surgery were included. Retinal autofluorescence was excited with 470 nm, and amplitude-weighted mean fluorescence lifetimes (Tm) were measured in a short spectral channel (SSC, 498-560 nm) and a long spectral channel (LSC, 560-720 nm). Tm were obtained within a standardized Early Treatment Diabetic Retinopathy Study grid and correlated with Tm. The unaffected fellow eye served as control. RESULTS: Fifty-eight patients (age: 65 ± 1.6 years, 11 women) were imaged at median 1.5 months postoperatively. Tm were significantly prolongxxxed within areas of previously detached retina in the long spectral channel and particularly in the central subfield in the short spectral channel. Short lifetimes in the center of the Early Treatment Diabetic Retinopathy Study grid correlated with better visual acuity (short spectral channel; r = 0.18, P = 0.001, long spectral channel; r = 0.08, P = 0.03). Areas of residual subretinal fluid pockets in four RRD eyes displayed short fluorescence lifetimes. CONCLUSION: Areas of previously detached retina exhibit significant fluorescence lifetime changes. We found a significant correlation of fluorescence lifetimes within the fovea with visual acuity after successful RRD repair. Our data suggests that the prolongation of fluorescence lifetimes in the fovea is mainly driven by loss of macular pigment. Therefore, fluorescence lifetime imaging ophthalmoscopy may be useful in the prediction of long-term functional outcomes after macula-off RRD surgery.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Jaggi D, Solberg Y, Dysli C, et al. FLUORESCENCE LIFETIME IMAGING OPHTHALMOSCOPY: Findings After Surgical Reattachment of Macula-Off Rhegmatogenous Retinal Detachment. Retina. 2020. PMID: 31860523. doi:10.1097/IAE.0000000000002718

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。