文献速递眼整形与眼眶

铂段链上眼睑负载治疗兔眼的长期结局:一种可调整方法

Long-Term Outcomes of Upper Eyelid Loading with Platinum Segment Chains for Lagophthalmos: An Adjustable Approach.
PubMed 文献 · Am J Ophthalmol · 2019-11-23

该连续病例系列报告了2013至2018年间117例患者122眼上睑植入铂段链治疗兔眼的5年结局。所有级别兔眼均显著改善,平均随访17.4个月,29.5%眼需修正手术,无铂过敏发生。铂段链可术后调整、成本较低且过敏风险低于黄金,被认为是兔眼一线负载植入物。

要点

  • 铂段链负载显著减少眨眼、轻闭和用力闭眼时的兔眼,并降低MRD1。
  • 29.5%的眼睑在植入后平均9.1个月接受修正手术,5.0%需2次以上手术。
  • 无铂过敏发生,77.5%眼睑无突出,70.8%眼睑轮廓正常。

核心结论

  • 铂段链是兔眼理想的一线负载植入物,兼具铂链优点并可术后调整、降低成本、减少过敏。

研究设计与样本

  • 连续病例系列,2013至2018年共117例患者122眼上睑植入铂段链,平均重量1.2±0.2 g(范围0.8-1.6 g),中位随访17.4个月。

主要发现

  • 所有级别兔眼均减少(P < 0.001),眨眼、轻闭和用力闭眼平均分别减少3.6、2.5和1.5 mm。
  • 平均MRD1减少1.4 mm(P < 0.001)。
  • 36眼(29.5%)在植入后9.1±9.2个月接受修正手术,其中6眼(5.0%)需2次或以上手术。
  • 无铂过敏发生;77.5%眼睑无突出,70.8%眼睑轮廓正常。

关键数值与推荐

  • 使用0.4 g和0.2 g铂段组装成所需重量,置于上睑板上位置,前提是已行提上睑肌腱膜后退。

临床怎么用

  • 对于兔眼患者,可考虑将铂段链作为一线负载植入物,利用其可术后调整的特性个体化处理。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This article reports the outcomes of a 5-year series of individually sutured platinum segment chains for upper eyelid loading. DESIGN: Consecutive case series. METHODS: Platinum segments of 0.4 and 0.2 g were assembled to create the desired weight and were placed in a supratarsal location after levator aponeurosis recession. Primary outcome measures included lagophthalmos on blink, gentle and forced eyelid closure, upper eyelid margin-to-reflex distance (MRD1), corneal staining, static and dynamic validated scoring for facial palsy patients, and complications. Secondary outcome measures were visual acuity, occurrence of induced ptosis, need for further surgery, cosmesis, and quality of life evaluation. RESULTS: During 2013-2018, a total of 122 upper eyelids of 117 patients received platinum segment chains (mean weight, 1.2 ± 0.2 g; range, 0.8-1.6 g) for lagophthalmos. Median follow-up was 17.4 months. All grades of lagophthalmos were reduced (P < 0.001), with mean reductions of 3.6, 2.5, and 1.5 mm on blink, gentle, and forced closures, respectively. Mean MRD1 was reduced by 1.4 mm (P < 0.001). Overall, 36 eyelids (29.5%) underwent revision surgery at 9.1 ± 9.2 months after implantation. Of those, 6 eyelids (5.0%) required 2 or more procedures. No platinum allergy occurred. The chain was graded as having no prominence in 77.5% of eyelids; the eyelids were graded as having a normal contour in 70.8% of cases. CONCLUSIONS: Platinum segments are US Food and Drug Administration approved and provide benefits of platinum chains with the additional advantages of allowing postoperative adjustability, reduced health care costs, and less likelihood of inducing allergy than gold. Platinum segments are an ideal first-line loading implant for lagophthalmos.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Ben Artsi E, Ullrich K, Brusasco L, et al. Long-Term Outcomes of Upper Eyelid Loading with Platinum Segment Chains for Lagophthalmos: An Adjustable Approach. Am J Ophthalmol. 2019. PMID: 31765627. doi:10.1016/j.ajo.2019.11.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。