文献速递角膜与眼表疾病

三维内皮/后弹力层复合体厚度图在活动性角膜移植排斥中的诊断效能

Diagnostic Performance of Three-Dimensional Endothelium/Descemet Membrane Complex Thickness Maps in Active Corneal Graft Rejection.
PubMed 文献 · Am J Ophthalmol · 2019-11-01

活动性排斥植片的区域TCT与En/DMT均显著高于健康角膜和透明植片(P<.001)。中央、旁中央、周边En/DMT诊断活动性排斥的敏感度和特异度均达100%,优于中央TCT的82%敏感度和96%特异度。

要点

  • 中央、旁中央、周边En/DMT诊断活动性排斥的敏感度和特异度均达100%。
  • En/DMT各区域与排斥严重程度显著相关(r=0.972、0.729、0.823,P<.001)。
  • 中央TCT诊断活动性排斥的敏感度为82%、特异度为96%。

核心结论

  • 三维En/DMT图诊断活动性角膜移植排斥具有很高的准确度、敏感度和特异度。

研究设计与样本

  • 采用高清光学相干断层扫描(HD-OCT)成像,并用定制分割算法生成中央6mm角膜TCT与En/DMT的三维彩色编码图。

主要发现

  • 活动性排斥植片的区域TCT和En/DMT均显著高于健康角膜和透明植片(P<.001)。
  • 中央、旁中央、周边En/DMT诊断活动性排斥的敏感度和特异度均为100%,最佳截断值分别为19μm、24μm、26μm。
  • 中央TCT诊断活动性排斥的敏感度为82%、特异度为96%,最佳截断值为587μm。
  • 中央、旁中央、周边En/DMT与排斥严重程度显著相关(r=0.972、r=0.729、r=0.823,P<.001)。

关键数值与推荐

  • 中央En/DMT最佳截断值19μm,诊断活动性排斥的敏感度和特异度均为100%。
  • 旁中央En/DMT最佳截断值24μm,诊断活动性排斥的敏感度和特异度均为100%。
  • 周边En/DMT最佳截断值26μm,诊断活动性排斥的敏感度和特异度均为100%。
  • 中央TCT最佳截断值587μm,诊断活动性排斥的敏感度82%、特异度96%。

临床怎么用

  • 可考虑用三维En/DMT图辅助诊断活动性角膜移植排斥,其区域厚度升高提示排斥。
  • En/DMT各区域与排斥严重程度相关,可能有助于评估病情严重度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the performance of 3-dimensional (3D) endothelium/Descemet membrane complex thickness (En/DMT) maps vs total corneal thickness (TCT) maps in the diagnosis of active corneal graft rejection. DESIGN: Cross-sectional study. METHODS: Eighty-one eyes (32 clear grafts and 17 with active rejection, along with 32 age-matched control eyes) were imaged using high-definition optical coherence tomography (HD-OCT), and a custom-built segmentation algorithm was used to generate 3D color-coded maps of TCT and En/DMT of the central 6-mm cornea. Regional En/DMT and TCT were analyzed and compared between the studied groups. Receiver operating characteristic curves were used to determine the accuracy of En/DMT and TCT maps in differentiating between studied groups. Main outcome measures were regional En/DMT and TCT. RESULTS: Both regional TCT and En/DMT were significantly greater in actively rejecting grafts compared to both healthy corneas and clear grafts (P < .001). Using 3D thickness maps, central, paracentral, and peripheral En/DMT achieved 100% sensitivity and 100% specificity in diagnosing actively rejecting grafts (optimal cut-off value [OCV] of 19 μm, 24 μm, and 26 μm, respectively), vs only 82% sensitivity and 96% specificity for central TCT, OCV of 587 μm. Moreover, central, paracentral, and peripheral En/DMT correlated significantly with graft rejection severity (r = 0.972, r = 0.729, and r = 0.823, respectively; P < .001). CONCLUSION: 3D En/DMT maps can diagnose active corneal graft rejection with excellent accuracy, sensitivity, and specificity. Future longitudinal studies are required to evaluate the predictive and prognostic role of 3D En/DMT maps in corneal graft rejection.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Eleiwa TK, Cook JC, Elsawy AS, et al. Diagnostic Performance of Three-Dimensional Endothelium/Descemet Membrane Complex Thickness Maps in Active Corneal Graft Rejection. Am J Ophthalmol. 2019. PMID: 31678558. doi:10.1016/j.ajo.2019.10.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。