气体填充对白内障联合玻璃体切割术后人工晶状体位置及屈光误差的影响:扫频眼前段OCT分析
回顾性病例系列研究,比较单纯白内障手术、无气体填充及有气体填充的白内障联合玻璃体切割术后人工晶状体位置与屈光结果。气体填充组术后1月近视漂移更明显,人工晶状体前移与屈光误差相关。
要点
- 气体填充组术后1月等效球镜预测误差为-0.82±0.64 D,近视漂移大于无气体填充组和单纯白内障组。
- 人工晶状体位置前移与术后1月屈光误差增大显著相关(R=0.53,P<0.001)。
- 气体消失后人工晶状体前固定仍可导致近视性屈光误差。
核心结论
- 在白内障联合玻璃体切割加气体填充眼中,人工晶状体前固定可导致近视性屈光误差,且气体消失后仍存在。
研究设计与样本
- 术前术后采用扫频眼前段OCT(CASIA2)测量前房及晶状体相关参数,光学生物测量(IOLMaster)测眼轴,术后1周和1月测屈光(等效球镜)。
主要发现
- 术后1月总体中位绝对误差(MedAE)为0.34 D,有气体填充组为0.47 D,大于无气体填充组(0.20 D)和单纯白内障组(0.31 D)。
- 术后1月总体平均屈光预测误差(ME)为-0.22±0.62 D,有气体填充组为-0.82±0.64 D,显著大于单纯白内障组(0.08±0.39 D)和无气体填充组(-0.07±0.45 D)(P<0.001,P<0.001)。
- 人工晶状体位置前移与术后1月屈光误差增大显著相关(R=0.53,P<0.001)。
关键数值与推荐
- 术后1月总体MedAE 0.34 D;有气体填充组0.47 D,无气体填充组0.20 D,单纯白内障组0.31 D。
- 术后1月总体ME -0.22±0.62 D;有气体填充组-0.82±0.64 D,单纯白内障组0.08±0.39 D,无气体填充组-0.07±0.45 D。
- 人工晶状体前移与ME相关性R=0.53,P<0.001。
临床怎么用
- 白内障联合玻璃体切割加气体填充术后应注意人工晶状体前移导致的近视漂移,即使气体已吸收。
- 可利用扫频眼前段OCT评估人工晶状体位置,辅助解释术后屈光误差。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To investigate the intraocular lens (IOL) position and refractive outcomes after cataract surgery and phacovitrectomy using swept-source anterior segment OCT (SS-ASOCT). DESIGN: Retrospective case series. PARTICIPANTS: Patients underwent cataract surgery (group A: 34 eyes), phacovitrectomy without gas tamponade (group B: 20 eyes), and phacovitrectomy with gas tamponade (group C: 22 eyes). METHODS: Various parameters associated with the anterior chamber and lens were measured by SS-ASOCT (CASIA2; Tomey Corp, Nagoya, Japan) before and after surgery. Axial lengths were measured by optical biometry (IOLMaster; Carl Zeiss, Oberkochen, Germany). The refraction (spherical equivalent) was measured 1 week and 1 month after surgery. MAIN OUTCOME MEASURES: Refractive outcomes and the parameters measured by SS-ASOCT were statistically evaluated. RESULTS: The overall mean median absolute error (MedAE) was 0.34 diopters (D) at 1 month postoperatively. The MedAE was greater in group C (0.47 D) than in group A (0.31 D) and group B (0.20 D). The overall mean refractive prediction error (ME) was -0.22±0.62 D at 1 month postoperatively. The ME was significantly greater in group C (-0.82±0.64 D) than in group A (0.08±0.39 D) and group B (-0.07±0.45 D) (P < 0.001, P < 0.001), indicating a greater myopic shift in group C. The forward movement of the IOL position was significantly correlated with a greater ME at 1 month (R = 0.53, P < 0.001). CONCLUSIONS: Forward fixation of the IOL caused myopic refractive errors even after the gas had disappeared in eyes that underwent phacovitrectomy with gas tamponade.
引用
- Shiraki N, Wakabayashi T, Sakaguchi H, et al. Effect of Gas Tamponade on the Intraocular Lens Position and Refractive Error after Phacovitrectomy: A Swept-Source Anterior Segment OCT Analysis. Ophthalmology. 2019. PMID: 31767435. doi:10.1016/j.ophtha.2019.10.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。