文献速递白内障与屈光手术角膜与眼表疾病

圆锥角膜眼人工晶状体公式的准确性

Accuracy of Intraocular Lens Formulas in Eyes With Keratoconus.
PubMed 文献 · Am J Ophthalmol · 2019-11-23

该回顾性病例系列纳入73只圆锥角膜眼,评估Hoffer Q、SRK/T、Holladay I、Holladay II、Haigis和Barrett Universal II公式的屈光准确性。所有公式均呈远视漂移,Barrett Universal II在轻中度病变中表现最准,Haigis在III期病变中误差最低。Pentacam角膜测值低于光学生物测量,可能有助于避免远视结果。

要点

  • 所有公式在圆锥角膜眼中均呈远视漂移,平均预测误差为+0.10至+4.38D。
  • Barrett Universal II在I期和II期眼中绝对误差中位数最低(均为0.445D)。
  • III期眼样本仅5只,Haigis公式预测误差中位数最低(1.90D)。

核心结论

  • 所有人工晶状体公式在圆锥角膜眼中均倾向于产生远视漂移。
  • Barrett Universal II公式对轻中度圆锥角膜最为准确。
  • Pentacam角膜测值可能有助于避免远视结果。

研究设计与样本

  • 回顾性病例系列,纳入2014至2018年单中心圆锥角膜眼行无并发症白内障手术者。
  • 共纳入73只眼,排除术后最佳矫正视力差于20/40、多焦点晶状体、既往眼科手术及眼外伤者。
  • 按圆锥角膜严重程度分层,分析Hoffer Q、SRK/T、Holladay I、Holladay II、Haigis和Barrett Universal II公式。

主要发现

  • 所有公式平均预测误差为正值,范围0.10至4.38D。
  • Barrett Universal II在I期(n=46)和II期(n=22)眼中绝对误差中位数最低,均为0.445D。
  • Barrett Universal II在I期和II期眼中预测误差在±0.50D内的比例最高,分别为52%和50%。
  • III期眼(n=5)中Haigis公式预测误差中位数最低(1.90D),预测误差在±0.50D内比例最高(40%)。
  • 光学生物测量测得的角膜屈光力高于Pentacam角膜地形图测值。

关键数值与推荐

  • Barrett Universal II在I期和II期眼中绝对误差中位数为0.445D。
  • Haigis在III期眼中预测误差中位数为1.90D。

临床怎么用

  • 对轻中度圆锥角膜白内障患者,可优先考虑Barrett Universal II公式以减少屈光误差。
  • 所有公式均需警惕术后远视漂移,术前应告知患者相关风险。
  • 可结合Pentacam角膜测值辅助制定手术方案,以降低远视结果风险。

局限性

  • 回顾性设计,样本量有限,III期眼仅5只。
  • 未报告各公式在更晚期圆锥角膜中的比较数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the refractive accuracy of current intraocular lens (IOL) formulas in eyes with keratoconus. DESIGN: Retrospective case series. METHODS: Preoperative optical biometry, Pentacam topography, and postoperative outcomes were collected from eyes with keratoconus that had uncomplicated cataract surgery between 2014 and 2018 at a single institution. Exclusion criteria include postoperative best-corrected spectacle visual acuity worse than 20/40, multifocal lens, prior ophthalmic surgeries, and prior ocular trauma. The Hoffer Q, SRK/T, Holladay I, Holladay II, Haigis, and Barrett Universal II formulas were analyzed in each eye stratified by keratoconus severity. RESULTS: A total of 73 eyes were included. All formulas had a positive mean predicted error ranging from 0.10 to 4.38 diopters (D). The Barrett Universal II formula had the lowest median absolute error for stage I (n = 46, 0.445 D) and II (n = 22, 0.445 D) eyes, and the highest percentage of eyes with predicted error within ±0.50 D for both stage I (52%) and II (50%) eyes. In stage III eyes (n = 5), the Haigis formula had the lowest median predicated error (1.90 D) and the highest percentage of eyes with predicted error within ±0.50 D (40%). Corneal power measured by optical biometers was higher than measurements by Pentacam keratometry. CONCLUSIONS: All formulas tend to have a hyperopic surprise. The Barrett Universal II formula was the most accurate for mild to moderate disease. Pentacam keratometry may help avoid hyperopic outcomes.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Wang KM, Jun AS, Ladas JG, et al. Accuracy of Intraocular Lens Formulas in Eyes With Keratoconus. Am J Ophthalmol. 2019. PMID: 31770511. doi:10.1016/j.ajo.2019.11.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。