文献速递青光眼

青光眼标准视野与SD-OCT短期和长期变异性比较

Comparison of Short- And Long-Term Variability in Standard Perimetry and Spectral Domain Optical Coherence Tomography in Glaucoma.
PubMed 文献 · Am J Ophthalmol · 2019-11-09

该前瞻性队列研究纳入43只青光眼眼,比较标准自动视野计(SAP)平均偏差(MD)和谱域光学相干断层扫描(SD-OCT)全局视网膜神经纤维层(RNFL)厚度在短期(5周内)和长期(每年一次,平均4.0年)的变异性。结果显示长期变异性显著高于短期变异性,提示基于短期变异性建立的事件算法可能低估长期变异、高估进展。

要点

  • 青光眼患者SAP MD和SD-OCT RNFL厚度的长期变异性均显著高于短期变异性。
  • SAP MD短期残差SD为0.61±0.34 dB,长期为1.05±0.70 dB(P<0.001)。
  • SD-OCT RNFL厚度短期残差SD为0.81±0.56 μm,长期为1.95±1.86 μm(P<0.001)。

核心结论

  • 在青光眼患者中,SD-OCT和SAP的长期变异性均高于短期变异性。
  • 基于短期变异性数据建立规范数据库的事件算法可能低估长期变异性,从而可能高估进展。

研究设计与样本

  • 前瞻性队列研究,纳入43例青光眼患者的43只眼。
  • 对SAP MD和SD-OCT全局RNFL厚度随时间进行普通最小二乘线性回归,短期测试在5周内完成,长期测试每年一次、平均4.0±0.8年。
  • 通过残差的标准差衡量变异性,使用Wilcoxon符号秩检验比较短期与长期变异性。

主要发现

  • 短期变异性评估中,受试者平均完成4.5±0.8次SAP和OCT测试;长期变异性评估中完成相同次数测试,结果每年收集一次、平均4.0±0.8年。
  • SAP MD的残差平均SD长期为1.05±0.70 dB,短期为0.61±0.34 dB(P<0.001)。
  • SD-OCT RNFL厚度的残差平均SD长期为1.95±1.86 μm,短期为0.81±0.56 μm(P<0.001)。

临床怎么用

  • 临床解读青光眼进展时需注意长期变异性高于短期变异性,避免仅依据短期变异性阈值判断进展。
  • 对基于短期变异性规范数据库的事件算法检测到的进展应谨慎解释,警惕高估进展的可能。

局限性

  • 样本量较小,仅43只眼。
  • 长期随访平均4.0±0.8年,可能不足以反映更长期变异性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess short- and long-term variability on standard automated perimetry (SAP) and spectral domain optical coherence tomography (SD-OCT) in glaucoma. DESIGN: Prospective cohort. METHODS: Ordinary least squares linear regression of SAP mean deviation (MD) and SD-OCT global retinal nerve fiber layer (RNFL) thickness were fitted over time for sequential tests conducted within 5 weeks (short-term testing) and annually (long-term testing). Residuals were obtained by subtracting the predicted and observed values, and each patient's standard deviation (SD) of the residuals was used as a measure of variability. Wilcoxon signed-rank test was performed to test the hypothesis of equality between short- and long-term variability. RESULTS: A total of 43 eyes of 43 glaucoma subjects were included. Subjects had a mean 4.5 ± 0.8 SAP and OCT tests for short-term variability assessment. For long-term variability, the same number of tests were performed and results annually collected over an average of 4.0 ± 0.8 years. The average SD of the residuals was significantly higher in the long-term than in the short-term period for both tests: 1.05 ± 0.70 dB vs. 0.61 ± 0.34 dB, respectively (P < 0.001) for SAP MD and 1.95 ± 1.86 μm vs. 0.81 ± 0.56 μm, respectively (P < 0.001) for SD-OCT RNFL thickness. CONCLUSIONS: Long-term variability was higher than short-term variability on SD-OCT and SAP. Because current event-based algorithms for detection of glaucoma progression on SAP and SD-OCT have relied on short-term variability data to establish their normative databases, these algorithms may be underestimating the variability in the long-term and thus may overestimate progression over time.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Urata CN, Mariottoni EB, Jammal AA, et al. Comparison of Short- And Long-Term Variability in Standard Perimetry and Spectral Domain Optical Coherence Tomography in Glaucoma. Am J Ophthalmol. 2019. PMID: 31715158. doi:10.1016/j.ajo.2019.10.034

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。