这项横断面研究对39例青光眼和31例年龄匹配正常人的一只眼进行4.5-mm OCTA视盘扫描,测量视盘周围视网膜神经纤维层丛毛细血管密度(NFLP-CD),并按扩展Garway-Heath方案分为8个象限模拟24-2视野。模拟与实测视野最差象限在同一或相邻半球位置的一致率为97%,NFLP-MD在早、中、重度青光眼的差值分别为-0.9±2.0、0.9±2.9、5.8±3.2 dB,且重现性优于VF-MD。
要点
- OCTA模拟视野与实测24-2视野在损害位置和严重度上总体一致,重度青光眼倾向于低估严重度。
- NFLP-MD的访间重现性优于VF-MD(合并标准差0.63 dB对1.03 dB,P=.015)。
- NFLP-MD诊断敏感性显著高于VF-MD(P<.001)和整体NFL厚度(P=.031)。
核心结论
- 基于OCTA的模拟视野在青光眼损害位置和严重度上与实测24-2视野高度一致,但重度青光眼时模拟倾向于低估严重度。
- NFLP-MD重现性优于实际VF-MD,且诊断准确性优于VF-MD和整体NFL厚度,有望用于青光眼监测和早期诊断。
研究设计与样本
- 横断面研究,纳入39例青光眼和31例年龄匹配正常参与者,每人均取一只眼进行分析。
- 使用以视盘为中心的4.5-mm OCTA扫描测量视盘周围视网膜神经纤维层丛毛细血管密度(NFLP-CD,%面积)。
- 将NFLP-CD和24-2视野图按扩展Garway-Heath方案分为8个对应象限,并将象限NFLP-CD转换为对数dB尺度以生成模拟视野偏差图。
主要发现
- 模拟与实测24-2视野图比较,最差象限位于同一或相邻半球同一位置的比例为97%。
- 早、中、重度青光眼阶段NFLP-MD与VF-MD的差值分别为-0.9±2.0、0.9±2.9、5.8±3.2 dB。
- NFLP-MD的访间重现性优于VF-MD(合并标准差0.63 dB对1.03 dB,P=.015)。
- NFLP-MD诊断敏感性显著高于VF-MD(P<.001)和整体NFL厚度(P=.031)。
关键数值与推荐
- 模拟与实测视野最差象限在同一或相邻半球位置的一致率为97%。
- NFLP-MD与VF-MD差值:早期-0.9±2.0 dB、中度0.9±2.9 dB、重度5.8±3.2 dB。
- NFLP-MD访间重现性合并标准差0.63 dB,VF-MD为1.03 dB(P=.015)。
- NFLP-MD诊断敏感性高于VF-MD(P<.001)和整体NFL厚度(P=.031)。
临床怎么用
- 可利用OCTA测量的NFLP-CD生成模拟视野,辅助评估青光眼损害的位置和严重度。
- NFLP-MD重现性较好,可作为青光眼随访监测的补充指标。
- NFLP-MD诊断敏感性较高,可能有助于早期青光眼诊断。
- 对重度青光眼,模拟视野可能低估严重度,解读时需结合实测视野。
局限性
- 为横断面研究,样本量有限(39例青光眼和31例正常对照)。
- 重度青光眼时模拟视野倾向于低估严重度。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To simulate 24-2 visual field (VF) using optical coherence tomographic angiography (OCTA) for glaucoma evaluation. DESIGN: Cross-sectional study. METHODS: One eye each of 39 glaucoma and 31 age-matched normal participants was scanned using 4.5-mm OCTA scans centered on the disc. The peripapillary retinal nerve fiber layer plexus capillary density (NFLP-CD, %area) was measured. The NFLP-CD and 24-2 VF maps were divided into 8 corresponding sectors using an extension of Garway-Heath scheme. RESULTS: Sector NFLP-CD was transformed to a logarithmic dB scale and converted to sector simulated VF deviation maps. Comparing simulated and actual 24-2 VF maps, the worst sector was in the same or adjacent location in the same hemisphere 97% of the time. VF mean deviation (VF-MD) was simulated by NFLP mean deviation (NFLP-MD). The differences between NFLP-MD and VF-MD in early, moderate, and severe glaucoma stages were -0.9 ± 2.0, 0.9 ± 2.9, and 5.8 ± 3.2 dB. NFLP-MD had better (P = .015) between-visit reproducibility (0.63 dB pooled standard deviation) than VF-MD (1.03 dB). NFLP-MD had a significantly higher sensitivity than VF-MD (P < .001) and overall NFL thickness (P = .031). CONCLUSIONS: OCTA-based simulated VF agreed well with actual 24-2 VF in terms of both the location and severity of glaucoma damage, with the exception of severe glaucoma in which the simulation tended to underestimate severity. The NFLP-MD had better reproducibility than actual VF-MD and holds promise for improving glaucoma monitoring. The NFLP-MD had better diagnostic accuracy than both VF-MD and overall NFL thickness and may be useful for early glaucoma diagnosis.