该回顾性病例对照研究纳入188例青光眼患者的188只眼,评估艾哈迈德阀植入术后脉络膜脱离的发生率及危险因素。广角眼底照相检出率为35.1%,45度眼底照相为16.9%;多因素分析显示年龄、假性剥脱性青光眼、人工晶状体眼和高血压是独立危险因素,前房塌陷仅与短眼轴相关。

要点

  • 广角眼底照相可提高艾哈迈德阀术后脉络膜脱离的检出率。
  • 假性剥脱性青光眼、高龄、人工晶状体眼和高血压增加脉络膜脱离风险。
  • 前房塌陷风险仅与短眼轴相关。

核心结论

  • 艾哈迈德阀植入术后脉络膜脱离的风险与青光眼病因(假性剥脱)、高龄、人工晶状体眼和高血压相关。

研究设计与样本

  • 回顾性病例对照研究,纳入188例青光眼患者的188只眼,均行艾哈迈德阀植入术,根据有无脉络膜脱离分组分析。

主要发现

  • 广角眼底照相下脉络膜脱离发生率为35.1%,45度眼底照相下为16.9%。
  • 术前术后眼压差越大,脉络膜脱离范围越大。
  • 前房塌陷风险仅与短眼轴相关。

关键数值与推荐

  • 脉络膜脱离组与非脱离组在年龄、中央角膜厚度、眼轴长度、青光眼病因、白内障或青光眼病史、高血压、糖尿病和视野严重程度(MD)方面存在差异。

临床怎么用

  • 对假性剥脱性青光眼、高龄、人工晶状体眼合并高血压的患者,术后应加强脉络膜脱离监测,可考虑使用广角眼底照相。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess the incidence and risk factors related to choroidal detachment after glaucoma drainage device (Ahmed valve) implantation. DESIGN: Retrospective case-control study. METHODS: A total of 188 eyes of 188 glaucoma patients were enrolled who underwent Ahmed valve implantation surgery. Patients were divided into 2 groups according to the presence or absence of choroidal detachment. The data were analyzed for factors associated with choroidal detachment. Separately, we divided eyes with choroidal detachment into 2 subgroups according to severity and conducted a subanalysis. In addition, we also analyzed the factors associated with chamber collapse. RESULTS: The incidence of choroidal detachment was 35.1% according to wide-field fundus photography and 16.9% according to 45-degree fundus photography. The current study showed that age, central corneal thickness, axial length, etiology of glaucoma, history of cataract or glaucoma, hypertension, diabetes, and severity of the visual field (MD) were different between the choroidal detachment and nonchoroidal detachment groups. A multivariate analysis showed significant differences in age (P = .035), etiology of glaucoma (pseudoexfoliation; PEX) (P = .028), lens status (pseudophakia) (P = .011), and hypertension (P = .011). The greater the intraocular pressure difference before and after surgery, the greater the size of the choroidal detachment. Chamber collapse risk was associated with only short axial length. CONCLUSION: The detection of choroidal detachment after Ahmed valve implantation can be increased according to the introduction of wide fundus photography. The risk of choroidal detachment is associated with the etiology of glaucoma (PEX), older age, pseudophakia (lens status), and hypertension.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Shin DY, Jung KI, Park HYL, et al. Risk Factors for Choroidal Detachment After Ahmed Valve Implantation in Glaucoma Patients. Am J Ophthalmol. 2019. PMID: 31730841. doi:10.1016/j.ajo.2019.10.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。