探索青光眼诊断中OCT诊断研究产出与临床使用之间的差距
该横断面比较性诊断试验研究纳入280名白种人受试者,评估OCT参考数据库分类诊断青光眼的敏感性与特异性,并与连续参数ROC曲线在匹配特异性下的敏感性比较。结果显示,视网膜神经纤维层厚度分类的敏感性与连续参数相似,而最小边缘宽度分类的敏感性显著低于连续参数。参考数据库分类的诊断准确性可能低于诊断研究中连续参数ROC曲线外推的准确性。
要点
- 在匹配特异性下,视乳头周围视网膜神经纤维层厚度分类的敏感性与连续参数相似。
- 最小边缘宽度分类的敏感性显著低于对应的连续参数。
- 参考数据库分类的诊断准确性可能低于连续参数ROC曲线外推的准确性。
核心结论
- 参考数据库分类的诊断准确性可能低于诊断研究中连续参数ROC曲线外推的准确性。
- 两种方法准确性的差距可用于估计特定参考数据库应用于连续参数诊断时的可靠性。
研究设计与样本
- 横断面、比较性诊断试验研究,纳入连续受试者,来自意大利多中心青光眼影像研究(MIGIS)。
- 共纳入280名白种人受试者,通过OCT测量整体和分区视乳头周围视网膜神经纤维层厚度和最小边缘宽度。
主要发现
- 在匹配特异性下,视乳头周围视网膜神经纤维层厚度分类的敏感性与对应连续参数统计学相似。
- 在匹配特异性下,最小边缘宽度分类的敏感性显著低于对应连续参数。
关键数值与推荐
- 采用2×2表计算参考数据库分类的敏感性和特异性。
- 通过ROC曲线提取连续参数,并在匹配特异性下比较敏感性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: To explore the gap between diagnostic research outputs and clinical use of optical coherence tomography (OCT) in glaucoma and assess the reliability of a specific reference database when applied to a morphological imaging parameter for diagnostic purposes. METHODS: Consecutive subjects enrolled in the Multicenter Italian Glaucoma Imaging Study (MIGIS) have been included in this cross-sectional, comparative evaluation of diagnostic tests study. Patients underwent measurement of global and sectorial peripapillary retinal nerve fibre thickness (pRNFL) and minimum rim width (MRW) by OCT. The sensitivity and specificity of reference-database categorical classifications were calculated by means of 2×2 tables and sensitivity was compared with that of the corresponding continuous parameter extracted from the receiver operating characteristic (ROC) curves by matching the specificity. RESULTS: 280 Caucasian subjects have been included. At matched specificities, the sensitivity of pRNFL categorical classifications was statistically similar to that of the corresponding continuous parameters, whereas the sensitivity of the MRW categorical classifications was significantly lower than that of the corresponding continuous parameters. CONCLUSIONS: The diagnostic accuracy of reference database classifications might be lower than that extrapolated from the ROC curves of continuous parameters used in diagnostic research. The gap between the accuracy of these two approaches may be used to estimate the reliability of a specific reference database when applied to a continuous parameter for diagnostic purposes.
引用
- Michelessi M, Quaranta L, Riva I, et al. Exploring the gap between diagnostic research outputs and clinical use of OCT for diagnosing glaucoma. Br J Ophthalmol. 2019. PMID: 31732524. doi:10.1136/bjophthalmol-2019-314607
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。