文献速递青光眼神经眼科

大型社区队列中环境大气细颗粒物(PM2.5)与青光眼的关系

The Relationship Between Ambient Atmospheric Fine Particulate Matter (PM2.5) and Glaucoma in a Large Community Cohort.
PubMed 文献 · Invest Ophthalmol Vis Sci · 2019-01-01

基于英国生物银行111370名参与者的问卷、眼科测量和居住地空气质量数据,分析PM2.5浓度与自报青光眼、眼压及黄斑神经节细胞-内丛状层(GCIPL)厚度的关联。结果显示PM2.5每增加一个四分位间距,自报青光眼风险升高(OR=1.06,95%CI 1.01-1.12,P=0.02),GCIPL变薄(β=-0.56 μm,95%CI -0.63至-0.49,P=1.2×10^-53),且呈剂量反应关系(P<0.001);PM2.5与眼压无临床相关关系。

要点

  • PM2.5每增加一个IQR,自报青光眼OR=1.06(95%CI 1.01-1.12,P=0.02)。
  • PM2.5每增加一个IQR,GCIPL厚度减少0.56 μm(95%CI -0.63至-0.49,P=1.2×10^-53)。
  • PM2.5与眼压无临床相关关系,提示非眼压依赖机制。

核心结论

  • 较高PM2.5暴露与自报青光眼及该病的不良结构特征相关。
  • PM2.5与眼压无关联,提示该关系可能通过非眼压依赖机制发生,可能为神经毒性或血管效应。

研究设计与样本

  • 分析英国生物银行111370名参与者的问卷数据、眼科测量和居住区环境空气质量数据。
  • 选取空气动力学直径小于2.5 μm的颗粒物(PM2.5)作为空气质量暴露指标。
  • 眼科测量包括自报青光眼、眼压以及谱域光学相干断层扫描获得的九个早期治疗糖尿病视网膜病变研究(ETDRS)视网膜亚区黄斑神经节细胞-内丛状层(GCIPL)平均厚度。

主要发现

  • 居住于PM2.5浓度较高区域的参与者更可能报告青光眼诊断(每四分位间距增加,OR=1.06,95%CI 1.01-1.12,P=0.02)。
  • 较高PM2.5浓度与较薄GCIPL相关(每四分位间距增加,β=-0.56 μm,95%CI -0.63至-0.49,P=1.2×10^-53)。
  • 观察到较高PM2.5水平与较薄GCIPL之间存在剂量反应关系(P<0.001)。
  • PM2.5浓度与眼压之间无临床相关关系。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Glaucoma is more common in urban populations than in others. Ninety percent of the world's population are exposed to air pollution above World Health Organization (WHO) recommended limits. Few studies have examined the association between air pollution and glaucoma. METHODS: Questionnaire data, ophthalmic measures, and ambient residential area air quality data for 111,370 UK Biobank participants were analyzed. Particulate matter with an aerodynamic diameter < 2.5 μm (PM2.5) was selected as the air quality exposure of interest. Eye measures included self-reported glaucoma, intraocular pressure (IOP), and average thickness of macular ganglion cell-inner plexiform layer (GCIPL) across nine Early Treatment Diabetic Retinopathy Study (ETDRS) retinal subfields as obtained from spectral-domain optical coherence tomography. We examined the associations of PM2.5 concentration with self-reported glaucoma, IOP, and GCIPL. RESULTS: Participants resident in areas with higher PM2.5 concentration were more likely to report a diagnosis of glaucoma (odds ratio = 1.06, 95% confidence interval [CI] = 1.01-1.12, per interquartile range [IQR] increase P = 0.02). Higher PM2.5 concentration was also associated with thinner GCIPL (β = -0.56 μm, 95% CI = -0.63 to -0.49, per IQR increase, P = 1.2 × 10-53). A dose-response relationship was observed between higher levels of PM2.5 and thinner GCIPL (P < 0.001). There was no clinically relevant relationship between PM2.5 concentration and IOP. CONCLUSIONS: Greater exposure to PM2.5 is associated with both self-reported glaucoma and adverse structural characteristics of the disease. The absence of an association between PM2.5 and IOP suggests the relationship may occur through a non-pressure-dependent mechanism, possibly neurotoxic and/or vascular effects.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Chua SYL, Khawaja AP, Morgan J, et al. The Relationship Between Ambient Atmospheric Fine Particulate Matter (PM2.5) and Glaucoma in a Large Community Cohort. Invest Ophthalmol Vis Sci. 2019. PMID: 31764948. doi:10.1167/iovs.19-28346

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。