PubMed 文献 · Invest Ophthalmol Vis Sci · 2019-01-01

研究纳入25名受试者,在三次访视中使用Belmonte角膜感觉计测量10次连续持续泪暴露(STARE)试验前、后及30分钟后的角膜冷、机械和化学检测阈值。结果显示重复STARE试验后症状评分显著变化,机械阈值在30分钟后发生显著改变,而冷和化学阈值无显著变化。泪膜破裂与不适相关,提示泪膜不稳定可产生神经感觉改变。

要点

  • 25名受试者完成三次访视,每次经历10次连续STARE试验,每次试验均出现泪膜破裂,范围占暴露角膜面积的25%至88%。
  • CSQ症状在重复STARE后即刻和30分钟后均与试验前显著不同(Wilcoxon检验,P < 0.017)。

核心结论

  • STARE试验中的泪膜破裂与不适相关,重复后导致眼不适症状增加及30分钟后机械感觉阈值改变。
  • 结果提示泪膜不稳定可产生神经感觉改变,该不稳定被认为在干眼患者日常眨眼过程中反复发生。

研究设计与样本

  • 研究采用人类受试者模型,共25名受试者参与三次研究访视。
  • 使用计算机控制的Belmonte角膜感觉计估算冷、机械和化学刺激的角膜检测阈值,测量时间点为10次连续持续泪暴露(STARE)试验前、后及30分钟后。
  • 受试者在STARE试验期间转动疼痛旋钮(0-10)表示不适,并分析每次试验中泪膜破裂和变薄的面积。
  • 症状通过当前症状问卷(CSQ)评估。

主要发现

  • CSQ症状在两次访视中均存在显著时间效应(Friedman检验,P < 0.001),重复STARE后即刻和30分钟后均与STARE前显著不同(Wilcoxon检验,P < 0.017)。
  • 每次试验均发生泪膜破裂,范围占暴露角膜面积的25%至88%,所有受试者在试验期间均表示不适。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To use a human-based model to study the effects of repeated tear film instability on corneal detection thresholds to cold, mechanical, and chemical stimuli. METHODS: Twenty-five subjects participated in three study visits. A computer-controlled Belmonte esthesiometer was used to estimate corneal detection thresholds to cold, mechanical, and chemical stimuli before, after, and 30 minutes following 10 consecutive sustained tear exposure (STARE) trials. Subjects turned a pain knob (0-10) to indicate discomfort during STARE trials. The area of tear breakup and thinning in each trial was analyzed. Symptoms were evaluated by the Current Symptom Questionnaire (CSQ). RESULTS: There was a significant time effect on CSQ symptoms during both visits (Friedman test, P < 0.001), with immediately after repeated STARE and 30 minutes later significantly differing from before STARE (Wilcoxon, P < 0.017). Tear breakup occurred in every trial, ranging from 25% to 88% of the exposed corneal area and all subjects indicated discomfort during trials. There was a significant time effect on mechanical thresholds between before STARE mechanical thresholds and 30 minutes later (repeated measures analysis of variance [ANOVA] P < 0.001), but not cold (P = 0.057) or chemical (P = 0. 565) thresholds. CONCLUSIONS: In this study, tear breakup during STARE trials was associated with discomfort, which when repeated, resulted in increased symptoms of ocular discomfort and alterations of mechanical sensory thresholds after 30 minutes. These results suggest that tear film instability, which is thought to occur repeatedly during normal blinking among dry eye patients over the day, can produce neurosensory alterations.

来源:Invest Ophthalmol Vis Sci,查看原文。版权归原作者所有。

引用

  1. Awisi-Gyau D, Begley CG, Situ P, et al. Changes in Corneal Detection Thresholds After Repeated Tear Film Instability. Invest Ophthalmol Vis Sci. 2019. PMID: 31618427. doi:10.1167/iovs.19-27802

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。