糖尿病视网膜病变中视网膜毛细血管无灌注与动脉或静脉的关系:基于广域光学相干断层扫描血管成像的观察
研究纳入44例增殖型或非增殖型糖尿病视网膜病变患者的63只眼,利用光学相干断层扫描血管成像(OCTA)图像分析毛细血管无灌注与动脉或静脉的邻近关系。结果显示各期糖尿病视网膜病变中动脉邻近无灌注均大于静脉邻近无灌注,且无灌注面积较小时倾向于动脉邻近,面积较大时倾向于静脉邻近。
要点
- 各期糖尿病视网膜病变中动脉邻近无灌注均大于静脉邻近无灌注(P < 0.001)。
- 增殖型糖尿病视网膜病变总无灌注面积中位数8.93%大于中度非增殖型的3.49%(P < 0.01)。
- 动脉/静脉无灌注比值与总无灌注面积呈负相关(r = -0.600,P < 0.0001)。
核心结论
- 在糖尿病视网膜病变中,较小的无灌注倾向于动脉邻近,而较大的无灌注倾向于静脉。
研究设计与样本
- 纳入44例增殖型或非增殖型糖尿病视网膜病变患者的63只眼,其中37只眼另获取五个固视点的广域拼接图像。
- 使用Zeiss Plex Elite 9000获取以黄斑中心凹为中心的12×12毫米OCTA图像。
- 开发半自动算法检测全视网膜OCT层中的无灌注并计算其占图像总面积的百分比,手动追踪视网膜动脉和静脉,根据最短距离将无灌注像素标记为动脉侧或静脉侧。
主要发现
- 22只眼中度非增殖型、16只眼重度非增殖型、25只眼增殖型。
- 增殖型总无灌注面积中位数8.93%大于中度非增殖型的3.49%(P < 0.01)。
- 各期糖尿病视网膜病变中动脉邻近无灌注均大于静脉邻近无灌注(P < 0.001)。
- 动脉/静脉无灌注比值中位数在中度非增殖型为1.93、重度非增殖型为1.84、增殖型为1.78。
- 动脉/静脉无灌注比值与总无灌注面积呈负相关(r = -0.600,P < 0.0001),广域拼接图像结果呈现相似模式。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate whether retinal capillary nonperfusion is found predominantly adjacent to arteries or veins in eyes with diabetic retinopathy (DR). METHODS: Sixty-three eyes from 44 patients with proliferative DR (PDR) or non-PDR (NPDR) were included. Images (12 × 12-mm) foveal-centered optical coherence tomography (OCT) angiography (OCTA) images were taken using the Zeiss Plex Elite 9000. In 37 eyes, widefield montages with five fixation points were also obtained. A semiautomatic algorithm that detects nonperfusion in full-retina OCT slabs was developed, and the percentages of capillary nonperfusion within the total image area were calculated. Retinal arteries and veins were manually traced. Based on the shortest distance, nonperfusion pixels were labeled as either arterial-side or venous-side. Arterial-adjacent and venous-adjacent nonperfusion and the A/V ratio (arterial-adjacent nonperfusion divided by venous-adjacent nonperfusion) were quantified. RESULTS: Twenty-two eyes with moderate NPDR, 16 eyes with severe NPDR, and 25 eyes with PDR were scanned. Total nonperfusion area in PDR (median: 8.93%) was greater than in moderate NPDR (3.49%, P < 0.01). Arterial-adjacent nonperfusion was greater than venous-adjacent nonperfusion for all stages of DR (P < 0.001). The median A/V ratios were 1.93 in moderate NPDR, 1.84 in severe NPDR, and 1.78 in PDR. The A/V ratio was negatively correlated with the total nonperfusion area (r = -0.600, P < 0.0001). The results from the widefield montages showed similar patterns. CONCLUSIONS: OCTA images with arteries and veins traced allowed us to estimate the nonperfusion distribution. In DR, smaller nonperfusion tends to be arterial-adjacent, while larger nonperfusion tends toward veins.
引用
- Ishibazawa A, De Pretto LR, Alibhai AY, et al. Retinal Nonperfusion Relationship to Arteries or Veins Observed on Widefield Optical Coherence Tomography Angiography in Diabetic Retinopathy. Invest Ophthalmol Vis Sci. 2019. PMID: 31622467. doi:10.1167/iovs.19-26653
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。