文献速递青光眼

理解前节光学相干断层扫描与房角镜检查在房角关闭评估中的诊断不一致

Understanding diagnostic disagreement in angle closure assessment between anterior segment optical coherence tomography and gonioscopy.
PubMed 文献 · Br J Ophthalmol · 2019-09-06

在新加坡社区综合诊所连续招募2027名≥50岁有晶状体眼无相关眼病史受试者,行房角镜与SS-OCT全周房角评估。以≥50%圆周关闭为SS-OCT标准时,14.7%为过度诊断(假阳性);前房深度更深(OR 9.31)和晶状体拱高更低(OR 0.04)与假阳性诊断显著相关。

要点

  • SS-OCT以≥50%圆周虹膜小梁接触为房角关闭标准时,14.7%被房角镜判为开放而SS-OCT判为关闭(假阳性)。
  • 假阳性眼较两法均判为关闭的真阳性眼前房更宽(11.7 vs 11.6 mm,p<0.001)、前房更深(2.4 vs 2.2 mm,p<0.001)。
  • 多因素分析中,更深前房深度(OR 9.31)和更低晶状体拱高(OR 0.04)与假阳性诊断显著相关。

核心结论

  • 前房尺寸(由前房深度和晶状体拱高决定)是与SS-OCT和房角镜在房角关闭评估中诊断不一致显著相关的因素。

研究设计与样本

  • 横断面研究,连续纳入2027名年龄≥50岁、无相关既往眼病史的有晶状体眼受试者,来自新加坡一家社区综合诊所。

主要发现

  • 当SS-OCT以≥50%房角圆周关闭为标准时,272眼(14.7%)出现过度诊断结果(假阳性)。
  • 这些假阳性眼较两法均判为关闭的真阳性眼前房更宽(前房宽度11.7 vs 11.6 mm,p<0.001)且更深(前房深度2.4 vs 2.2 mm,p<0.001)。
  • 多因素分析中,更深前房深度(OR 9.31)和更低晶状体拱高(OR 0.04)与假阳性诊断显著相关。
  • 多数假阳性病例在SS-OCT图像上表现为短(52.6%)或不规则(39%)的虹膜小梁接触。

关键数值与推荐

  • 房角镜采用两象限关闭定义;SS-OCT房角关闭定义为虹膜小梁接触范围≥35%、≥50%和≥75%圆周角度。
  • 假阳性(过度诊断)定义为房角镜判为开放而SS-OCT判为关闭;假阴性(诊断不足)定义为房角镜判为关闭而SS-OCT判为开放。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND/AIMS: Although being a more objective tool for assessment and follow-up of angle closure, reliability studies have reported a moderate diagnostic performance for anterior segment optical coherence tomography (OCT) technologies when comparing with gonioscopy as the reference standard. We aim to determine factors associated with diagnostic disagreement in angle closure when assessed by anterior segment swept source OCT (SS-OCT, CASIA SS-1000; Tomey, Nagoya, Japan) and gonioscopy. METHODS: Cross-sectional study. A total of 2027 phakic subjects aged ≥50 years, with no relevant previous ophthalmic history, were consecutively recruited from a community polyclinic in Singapore. Gonioscopy and SS-OCT (128 radial scans) for the entire circumference of the angle were performed for each subject. A two-quadrant closed gonioscopic definition was used. On SS-OCT images, angle closure was defined as iridotrabecular contact (ITC) to the extent of ≥35%, ≥50% and ≥75% of the circumferential angle. Diagnostic disagreements between both methods, that is, false positives or overcalls and false negatives or undercalls were defined, respectively, as gonioscopic open/closed angles inversely assessed as closed/open by SS-OCT. RESULTS: Two hundred and seventy-two (14.7%) resulted in overcall results (false positives) when ≥50% of the angle circumference was closed using SS-OCT. These eyes had significantly wider (anterior chamber width, 11.7 vs 11.6 mm, p<0.001) and deeper (anterior chamber depth (ACD), 2.4 vs 2.2 mm, p<0.001) anterior chambers than eyes assessed by both methods as closed (true positives). Deeper ACD (OR 9.31) and lower lens vault (LV) (OR 0.04) were significantly associated with a false positive diagnosis in the multivariate analysis. Most of these cases had short (52.6%) or irregular (39%) ITC in SS-OCT images. CONCLUSIONS: We found that anterior chamber dimensions, determined by ACD and LV, were factors significantly associated with diagnostic disagreement between anterior segment SS-OCT and gonioscopy in angle closure assessment.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Porporato N, Baskaran M, Tun TA, et al. Understanding diagnostic disagreement in angle closure assessment between anterior segment optical coherence tomography and gonioscopy. Br J Ophthalmol. 2019. PMID: 31492674. doi:10.1136/bjophthalmol-2019-314672

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。