使用Pentacam Scheimpflug成像评估角膜厚度指标遗传力
该横断面人群研究在伊朗两个农村地区纳入1383名来自382个家庭的5岁以上参与者,使用Pentacam测量角膜顶点、入瞳中心、最薄点厚度及PPI和ARTmax,发现顶点角膜厚度遗传力最高(85%),ARTmax最低(27.62%),提示这些角膜厚度表型与遗传因素高度相关。
要点
- 角膜顶点厚度遗传力为85%,为所测指标中最高。
- 入瞳中心与最薄点角膜厚度遗传力分别为82.0%和77.0%。
- 平均PPI与ARTmax遗传力较低,分别为31.49%和27.62%。
核心结论
- 所测角膜厚度参数的高遗传力证实这些表型与遗传因素高度相关,作者呼吁开展遗传与分子研究以寻找相关基因并理解相关疾病(尤其是青光眼和圆锥角膜)的病因。
研究设计与样本
- 横断面人群研究,在随机选取的两个农村地区开展,纳入5岁及以上且父母中至少一方与至少一名子女共同参与的家庭成员,最终分析1383名来自382个家庭的个体。
主要发现
- 共3851名个体被选取,3314名参与研究,应用排除标准后1383名个体纳入分析,其中女性754名(54.52%)。
- 研究对象平均年龄37.23±19.35岁(范围6至93岁)。
- 角膜顶点厚度遗传力最高为85%,ARTmax遗传力最低为27.62%。
- 入瞳中心角膜厚度、最薄点角膜厚度和平均PPI的遗传力分别为82.0%、77.0%和31.49%。
关键数值与推荐
- 角膜顶点厚度遗传力85%。
- 入瞳中心角膜厚度遗传力82.0%。
- 最薄点角膜厚度遗传力77.0%。
- 平均PPI遗传力31.49%。
- ARTmax遗传力27.62%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To investigate the heritability of corneal thickness at the apex, entrance pupil centre, thinnest point, pachymetric progression index (PPI) and maximum Ambrósio relational thickness (ARTmax) using Pentacam. METHODS: The present cross-sectional and population-based study was conducted in two rural districts that were selected randomly. Individuals 5 years and older and data from households where one of the parents and at least one child participated in the study were considered for this analysis. All subjects were examined for visual acuity, refraction, biomicroscopy and, finally, Pentacam imaging. The heritability estimate was used to calculate familial aggregation of pachymetric indices. RESULTS: Of the 3851 selected individuals, 3314 participated in the study. After applying the exclusion criteria, a total of 1383 individuals from 382 households were included in the analysis; of these, 754 (54.52%) were female. The mean age of the subjects was 37.23±19.35 years (from 6 to 93 years). The highest heritability was observed for corneal thickness at the apex (85%), and the lowest was for ARTmax (27.62%). The heritability of other studied parameters, including corneal thickness at the entrance pupil centre, thinnest point and average PPI, was 82.0%, 77.0% and 31.49%, respectively. CONCLUSION: The high heritability of the mentioned pachymetric parameters confirms the high correlation between these phenotypes and genetic factors and calls for genetic and molecular research to find related genes and to understand the aetiology of associated diseases, especially glaucoma and keratoconus.
引用
- Hashemi H, Yekta A, Heydarian S, et al. Heritability of pachymetric indices using Pentacam Scheimflug imaging. Br J Ophthalmol. 2019. PMID: 31558493. doi:10.1136/bjophthalmol-2019-314640
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。