文献速递眼底病与葡萄膜炎青光眼白内障与屈光手术

基于技术的眼保健服务的诊断准确性:基于技术的眼保健服务比较试验第一部分

Diagnostic Accuracy of Technology-based Eye Care Services: The Technology-based Eye Care Services Compare Trial Part I.
PubMed 文献 · Ophthalmology · 2019-08-13

本研究前瞻性比较标准TECS协议与面对面检查对256例无已知显著眼病患者的诊断准确性,TECS阅读者对面对面检查设盲。结果显示TECS协议对白内障、糖尿病视网膜病变、青光眼/疑似青光眼及年龄相关性黄斑变性均有中等至高度一致性,总体敏感度和特异度分别≥75%和≥55%。作者认为标准TECS协议检测常见眼病准确,增加OCT等检查可进一步提升诊断能力。

要点

  • TECS阅读者与面对面检查对白内障(κ≥0.71)和糖尿病视网膜病变(κ≥0.61)呈高度一致。
  • 青光眼/疑似青光眼一致性中等至高度(κ≥0.52),年龄相关性黄斑变性一致性中等(κ≥0.34)。
  • 任何需转诊诊断的总体敏感度≥75%、特异度≥55%,各疾病类别一致率84.3%-98.4%。

核心结论

  • 标准TECS协议与面对面检查相比,检测常见眼病准确。
  • 增加OCT等额外检查可进一步提升诊断能力。

研究设计与样本

  • 前瞻性比较标准TECS协议与面对面检查,纳入256例无已知显著眼病史的患者。
  • 患者在同一天接受TECS协议筛查和面对面检查(金标准),TECS阅读者对面对面检查结果设盲。

主要发现

  • TECS阅读者与面对面检查相比,白内障一致性高度(κ≥0.71),糖尿病视网膜病变高度(κ≥0.61)。
  • 青光眼/疑似青光眼一致性中等至高度(κ≥0.52),年龄相关性黄斑变性一致性中等(κ≥0.34)。
  • 各疾病类别与TECS协议的一致率较高(84.3%-98.4%)。
  • 任何需转诊诊断的总体敏感度≥75%、特异度≥55%。
  • 大多数诊断的阅读者间和阅读者内一致性高度(κ>0.61),一致率范围66%-99%。

关键数值与推荐

  • 白内障κ≥0.71,糖尿病视网膜病变κ≥0.61,青光眼/疑似青光眼κ≥0.52,年龄相关性黄斑变性κ≥0.34。
  • 各疾病类别一致率84.3%-98.4%。
  • 任何需转诊诊断的总体敏感度≥75%、特异度≥55%。
  • 大多数诊断阅读者间和阅读者内κ>0.61,一致率66%-99%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Ophthalmologic telemedicine has the ability to provide eye care for patients remotely, and many countries have used screening tele-ophthalmology programs for several years. One such initiative at the Veterans Affairs (VA) Healthcare System is Technology-based Eye Care Services (TECS). The TECS services are located in primary care clinics and provide basic screening eye care, including vision, refraction, and retinal photography. Eye care providers ("readers") review the clinical data and recommend appropriate follow-up. One of the most common referrals from TECS has been for glaucoma, and this study was powered for glaucoma/glaucoma suspect detection. The current study was undertaken to identify aspects of the protocol that could be refined to enhance accuracy. DESIGN: Prospective comparison between the standard TECS protocol versus a face-to-face (FTF) examination on 256 patients, all of whom had no known history of significant ocular disease. PARTICIPANTS: Patients with no known ocular disease who were scheduled for an in-person eye appointment at the Atlanta VA. Patients underwent screening through the TECS protocol and received an FTF examination on the same day (gold standard). The TECS readers were masked to the results of the FTF examination. MAIN OUTCOME MEASURES: Percent agreement, kappa, sensitivity, and specificity were calculated for the TECS readers' interpretations versus the FTF examination. RESULTS: The TECS readers showed substantial agreement for cataract (κ ≥ 0.71) and diabetic retinopathy (κ ≥ 0.61) and moderate to substantial agreement for glaucoma/glaucoma suspect (κ ≥ 0.52) compared with an FTF examination. Age-related macular degeneration (AMD) showed moderate agreement (κ ≥ 0.34). Percent agreement with the TECS protocol was high (84.3%-98.4%) for each of the disease categories. Overall sensitivity and specificity were ≥75% and ≥55%, respectively, for any diagnosis resulting in referral. Inter-reader and intra-reader agreement was substantial for most diagnoses (κ > 0.61) with percent agreements ranging from 66% to 99%. CONCLUSIONS: Our results indicate that the standard TECS protocol is accurate when compared with an FTF examination for the detection of common eye diseases. The inclusion of additional testing such as OCT could further enhance diagnostic capability.

来源:Ophthalmology,查看原文。版权归原作者所有。

引用

  1. Maa AY, Medert CM, Lu X, et al. Diagnostic Accuracy of Technology-based Eye Care Services: The Technology-based Eye Care Services Compare Trial Part I. Ophthalmology. 2019. PMID: 31522900. doi:10.1016/j.ophtha.2019.07.026

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。